background image

 

 

 

 
 
Operating & Maintenance instruction manual 

 
 

 
 
OILLESS PISTON COMPRESSOR 

 

 

 
 

 

Tel: +39 02 9019180

 

www.mgfcompressors.com

MGF S.r.l.  Via Pascoli 15

 

20081 Abbiategrasso  (MI) - ITALY

 

Fax: +39 02 9019273 
Tel : +39 02 9019253/680 
e-mail: 

[email protected]

Beverage compressor 

 

Summary of Contents for S-OF050

Page 1: ...truction manual OILLESS PISTON COMPRESSOR Tel 39 02 9019180 www mgfcompressors com MGF S r l Via Pascoli 15 20081 Abbiategrasso MI ITALY Fax 39 02 9019273 Tel 39 02 9019253 680 e mail info mgfcompressors it Beverage compressor ...

Page 2: ...aulty manufacture for a period of 12 months from the date of purchase Please keep your receipt as proof of purchase This guarantee is invalid if the product is found to have been abused or tampered with in any way or not used for the purpose for which it was intended Faulty goods should be returned to their place of purchase no product can be returned without prior permission This guarantee does n...

Page 3: ...on Wait for compressor to cool down 12 For safe operation adjust the pressure regulator to the recommended setting as indicated by the specific tool or accessory being used for a particular usage and application 13 Not spray near any flames or areas where sparks or other sources of ignition may occur 14 Make sure that the area is well ventilated when using materials that give off fumes or sprays 1...

Page 4: ...is completely automatic and does not affect the compressing process However should problems develop with the cut in cut out settings please consult your MGF dealer NOTES a If the machine pumps continuously without cutting out then the compressor is too small for the application tool being used and damage may result Consult your MGF dealer b The motor is protected by a Thermal Overload which will t...

Page 5: ...n case of a performance drop please contact a specialized technician to replace consumables and sealing parts Periodicity check every 12 months is based on an use estimate of 1h day 1h of ON cycle with a max working cycle of 50 eg 50 sec ON 50 sec OFF in case of more critical uses correspondingly reduce check periodicity FAULT FINDING PROBLEM PROBABLE CAUSE REMEDY Compressor does not start or stop...

Page 6: ... filter blocked Bleed pipe from pressure switch to non return valve broken or disconnected Replace oil filler air filter plug Reconnect or replace bleed pipe SPECIFICATIONS MGF code Model description Air displacement Air delivery Motor Voltage frequency Air receiver Lt min CFM Lt min CFM HP Watt V Hz Lt S OF050 Beverage compressor 12 0 41 6 0 22 0 15 110 230 50 Not present MGF code Model descripti...

Page 7: ...RICATION ET LA FOURNITURE DES PRODUITS DECLARAMOS QUE BAJO NUESTRA RESPONSIBILIDAD EXCLUSIVA POR LA FABRICACION Y PROVISION EL NOSTRO PRODUCTO BEVERAGE LINE A CUI LA PRESENTE DICHIARAZIONE SI RIFERISCE SONO CONFORMI ALLE SEGUENTI DIRETTIVE CEE TO WHICH THIS DECLARATION RELATES ARE IN CONFORMITY WITH FOLLOWING DIRECTIVES CEE AUX QUELS CETTE DECLARATION EST LIEE SONT CONFORMES AUX NORMES MAJEURES SU...

Page 8: ...MGF S r l Via Pascoli 15 20081 Abbiategrasso MI ITALY Tel 39 02 9019253 680 Fax 39 02 9019273 e mail info mgfcompressors it www mgfcompressors com REV 01 2019 ...

Reviews: