background image

2

3

Gas Installation Codes

•  Appliances must be used in accordance with the 
  installation requirements of your gas supply  
  authority, or the Australian Standard AS 5601.
•  Appliances for use with bottled gas are labelled  
  ‘propane gas’.

Clearances

Minimum Clearances from combustible materials 
must be: 
Rear - 350mm    Sides - 300mm    Above - 600mm

Hose & Regulator Safety

The regulator and hose assembly supplied with the 
appliance are suitable for propane gas only.  
A gas regulator adjusted to have an outlet 
pressure of 2.75kPA is supplied for connection to 
the propane gas cylinder. The pressure regulator 
and hose assembly supplied with the appliance 
must be used. Replacement pressure regulators 
and hose assemblies must be those specified by 
the appliance manufacturer. 
When connecting the hose and regulator assembly 
to the gas cylinder, take care to avoid unnecessary 
twisting or kinking of the flexible hose.
After the assembly has been secured, turn on the 
gas and check for leaks by brushing a soap and 
water solution over all connections.
If you are unable to correct the leak by tightening 
the connections, turn off the gas and contact the 
supplier immediately.
Always ensure the appliance is kept away from 
flammable materials and the gas cylinder clear 
of any heat source. When changing over from 
an empty gas cylinder to a full one make sure 
this procedure is carried out in a flame free 
atmosphere.

Gas Cylinder Use & Safety

This is a low pressure appliance and must only be 
used with the hose and regulator supplied. It is 
designed for use with 9Kg propane gas cylinders 
certified to AS 2469.
The cylinder should be filled by a reputable gas 
supplier and visually inspected and re-qualified at 
each filling.
Always keep cylinder in an upright position. 

GENERAL INFORMATION

CONTENTS

Section

Page

General information

2-3

General assembly

4

Lighting procedure

4

Operating procedure

5

Care and maintenance

6

Assembly instructions

7-10

Natural gas conversion

11

Safe appliance locations

12

 

Side clearances of 300mm must  

 

be maintained to allow adequate  

 

airflow for combustion.

  Rear clearance of 350mm must be maintained 
  to avoid overheating surrounding surfaces.

For any queries or assistance call

Customer Service

Australia Only

1300 174 876

Hours of operation: 

Monday to Friday 8.30am - 5.30pm EST

Do not return to place of purchase.

Keep your purchase receipt, this will be 

required to make any claims under the 

12 month warranty.

Содержание P0104

Страница 1: ...za Oven with Stand Model No P0104 FOR OUTDOOR USE ONLY Cooks up to 3 pizzas at a time Use to cook a variety of food Easy clean vitreous enamel interior Powerful 22MJ h stainless steel burner Viewing window and temperature gauge Powder coated finish Cool touch handle Includes food safe ceramic pizza stone Rotary piezo ignition AGA Certified Propane gas Certified for conversion to Natural Gas ...

Страница 2: ...e gas and contact the supplier immediately Always ensure the appliance is kept away from flammable materials and the gas cylinder clear of any heat source When changing over from an empty gas cylinder to a full one make sure this procedure is carried out in a flame free atmosphere Gas Cylinder Use Safety This is a low pressure appliance and must only be used with the hose and regulator supplied It...

Страница 3: ...ad carefully before assembling and operating your appliance Location of your Appliance DO NOT use in garages porches sheds breezeways or other enclosed areas Your appliance is to be used OUTDOORS and is not intended to be installed in or on recreational vehicles and or boats and should not be placed on any surface that will burn Do not obstruct the flow of combustion and ventilation air around the...

Страница 4: ... at the burner ignition point check that the ignition lead is firmly attached to the control and sparker tip 3 Open the door and ensure that it remains open while lighting the burner 4 With sparking established turn the cylinder valve ON Then push and turn the control knob to HIGH 5 If the burner fails to light after several attempts turn off gas supply at cylinder and inspect for obstructions to ...

Страница 5: ...me to warm up before the food was applied Remove the food and give the burner time to pre heat 5 15 minutes There is too much food on the cooking surface Cook smaller portions IMPORTANT Note If the appliance cannot be adjusted to perform correctly it should not be used until serviced or repaired The door must be in the open position for lighting Do not smoke when attempting to ignite burner Do not...

Страница 6: ...urs in and around the burner immediately turn off gas at its source and turn the burner control to OFF wait until the appliance has cooled then clean the burner tubes and burner ports Preheating It is necessary to preheat the appliance for at least 15 minutes before cooking certain foods depending on the type of food and the cooking temperature Food that requires a low cooking temperature needs a ...

Страница 7: ...h Note Remove any transit protection material STEP 1 Lay the Pizza Oven on it s back and attach the washers and rubber feet by using 4 M5 screws 30mm long STEP 2 Stand the Pizza Oven on it s feet and attach the chimney to the body by using 3 M4 screws 8mm long Then attach the control knob ...

Страница 8: ...ion the wire racks ensuring the folded down tabs locate into the holes of the front of the rack supports Locate the ceramic stone into the bottom rack and position it at the rear of the appliance STEP 5 Attach the hose connection thread 1 4 B S P and tighten securely with a spanner Leak test using a soapy water solution ...

Страница 9: ...e legs with the dimples on the top frame Ensure foot A and Foot B are diagonally opposite each other note the legs angle out at the bottom from front to back STEP 7 Attach the base panel to the 4 leg assemblies using 16 M6 screws 8mm long and nuts FOOT A FOOT B Front 58 5cm Side 48cm FOOT A FOOT A FOOT B FOOT B Side 56 5cm Front 58 5cm ...

Страница 10: ...10 STEP 8 Locate the Pizza Oven on top of the stand as shown ...

Страница 11: ... plumbing and heating codes regarding sizing of the gas lines 3 All gas pipe connections must be sealed with a gas pipe compound resistant to Natural Gas 4 Installation of a drip leg if required in the gas supply line must conform to AS5601 5 When checking for gas leaks do not use an open flame Use a soap and water solution and check for bubbles indicating gas leakage 6 Installation of 1 8 NPT plu...

Страница 12: ...artial enclosure that includes an overhead cover and no more than two walls see Example 2 3 Within a partial enclosure that includes an overhead cover and more than two walls the following will apply at least 25 of the total wall area is completely open and at least 30 of the remaining wall area is open and unrestricted see Example 4 5 In the case of balconies at least 20 of the total wall area sh...

Отзывы: