10
11
WARNINGS
• Improper installation, adjustment, alteration,
service or maintenance can cause injury or
property damage.
• Read the instructions thoroughly before
installing or servicing this equipment.
• THIS APPLIANCE MUST NOT BE INSTALLED
OR USED INDOORS.
• NATURAL GAS APPLIANCE. TO BE INSTALLED
ONLY BY AN AUTHORISED PERSON.
• THE AUTHORISED PERSON WILL PROVIDE A
CERTIFICATE OF COMPLIANCE.
• A suitable AGA approved natural gas pressure
regulator must be installed in the pipeline and
be set at 1 kPa.
NATURAL GAS CONVERSION
TO BE INSTALLED ONLY ON OR IN A
NON-COMBUSTIBLE ENCLOSURE
Note: Recommended clearances must be maintained.
Tools Required:
• Adjustable spanner
• Phillips head screwdriver
GAS PIPING
1. (a) A minimum pipe diameter of 15mm is
required for inlet piping. A lever operated
shut-off valve should be installed within 1
metre of the appliance for servicing the unit.
(b) Where it is not practical to install solid tube
AGA certified stainless steel braided hose
can be installed. This hose assembly must
comply with AS5601 Gas Installations, pipe
sizing tables and shall not exceed 3 metres
in length. The internal diameter of the hose
must not be less than 10mm.
2. Check with local and state plumbing and
heating codes regarding sizing of the gas lines.
3. All gas pipe connections must be sealed with a
gas pipe compound resistant to Natural Gas.
4. Installation of a drip leg if required in the gas
supply line must conform to AS5601.
5. When checking for gas leaks, do not use an
open flame. Use a soap and water solution and
check for bubbles indicating gas leakage.
6. Installation of 1/8” NPT plugged tapping,
accessible for test gauge connections,
is required upstream of the gas supply
connection.
Warning
Improper installation, adjustment, alteration,
service or maintenance can cause injury
or property damage. Read the instructions
thoroughly before installing or servicing this
equipment.
SERVICING INSTRUCTIONS
Appliances should be serviced at least annually
and servicing must only be carried out by a
Licensed Plumber or Authorised Person.
Clean the Burner Ports and top with a Soft Brush.
Inspect and clean all combustion air inlets, then
replace the Burner ensuring it is firmly secured.
Minimum Clearance for Ventilation:
Rear
350 mm
Side
300 mm
NOTE TO INSTALLER:
1. The gas valve plug by-pass orifices must be
increased to:
1.5mm for low
2.15mm for medium
2. Drill the injector as per the data label
specifications or contact customer service on
1300 174 876 to order an injector kit.
TEST OPERATION OF APPLIANCE
BEFORE LEAVING.
Conversion ONLY to be done by an authorised person.