57
GASCOSEEKER 2-500 USER HANDBOOK
ARE BATTERIES REPLACED WHEN BAT OR BAT FAULT
INDICATOR IS ACTIVATED?
Batteries would normally be replaced when the BAT FAULT
flag is activated to achieve maximum battery life, however
a work programme should not be commenced with the
BAT flag activated and no spare batteries
The operational time between the BAT and BAT FAULT
flags depends on the particular batteries fitted, specific
instrument characteristics, ambient temperature and other
factors.
ACTION:
CHECK WHEN BATTERIES ARE
CHANGED.
IS INSTRUMENT SWITCHED OFF MANUALLY OR LEFT
TO SWITCH OFF AUTOMATlCALLY AFTER USE?
The instrument switches off automatically after 30 minutes
running, to conserve battery life, and to ensure that it is
unlikely you will be left with a non- functioning unit because
you forgot to switch it off.
If you do not switch the instrument off after use then each
operation of the instrument will be 30 minutes: if you only
use it for 5 minutes then the battery life may appear to be
excessive relative to use. The instrument has an internal
hours run counter that records the actual time operational
ACTION:
ALWAYS SWITCH INSTRUMENT OFF
MANUALLY AFTER USE