GASCOSEEKER 2-500 USER HANDBOOK
56
BATTERIES DO NOT GIVE LONG USE
HAVE NEW BATTERIES BEEN USED?
Alkaline batteries will give up to 15 hours use in normal
conditions, pre-used or poor quality batteries should not
be used in the instrument
ACTION:
REPLACE BATTERIES WITH FOUR NEW
LR2O ALKALINE CELLS.
ARE LR20 ALKALINE BATTERIES FITTED?
Only LR20 alkaline cells will give the specified instrument
performance.
ACTION:
USE ONLY LR 20 ALKALINE CELLS
ARE ALL FOUR BATTERIES OF THE SAME MAKE AND
TYPE?
All four batteries should be replaced at one time with new
cells of the same make and type
DO NOT MIX BATTERY TYPES
ACTION:
REPLACE ALL FOUR CELLS WITH NEW
LR20 ALKALINE CELLS
HAS INSTRUMENT BEEN USED AT LOW
TEMPERATURE?
The instrument performance of 15 hours is given at ambient
temperature between 15 Deg.C and 20 Deg.C; at lower
temperatures, particularly below freezing, battery capacity
can be dramatically reduced. Where the instrument is being
used at low temperature, replacement batteries should be
stored in warmer conditions where possible
ACTION:
CHECK INSTRUMENT PERFORMANCE
AT AMBIENT TEMPERATURES
Содержание Gascoseeker 2-500
Страница 1: ...Gascoseeker 2 500 User Handbook...
Страница 6: ...GASCOSEEKER 2 500 USER HANDBOOK iv...
Страница 12: ...GASCOSEEKER 2 500 USER HANDBOOK x...
Страница 49: ...37 GASCOSEEKER 2 500 USER HANDBOOK 4 Remove battery cover...
Страница 57: ...45 GASCOSEEKER 2 500 USER HANDBOOK Excess strap length can be clipped into open slot on top of strap clips...
Страница 86: ...GASCOSEEKER 2 500 USER HANDBOOK 74...