5.4
ERROR CODE TABLE-DIAGNOSTICS
CRITICAL FAILURES AND NON-CRITICAL FAILURES
Failures are classified as either "critical" or "non-critical". A critical failure
prevents the PD 6500
i
from operating and must be corrected immediately.
When a critical failure occurs, the audio alarm sounds, the overhead display
begins flashing and the message, SYSTEM FAILURE, appears on the LCD.
A non-critical failure does not prevent the PD 6500
i
from operating; however,
it should be corrected as soon as possible.
CRITICAL FAILURES
NON-CRITICAL FAILURES
• TX A or B FAIL
• NO SLAVE OUTPUT
• POWER MOD FAIL
• SLAVE SYNC
• RX BOARD FAIL
• AC SYNC or SYNC FAIL
• RX A or B ZN # PK FAIL
• RX or TX OPTIC FAIL
• CABLE MISCONNECT
• RX A or B ZN # BAL FAIL
• DSP FAIL
TABLE 5-4
Self Test: Possible Failures and Remedies
Failure
Verify and/or replace
Special Note
*TX A FAIL
1. Panel A cables & connectors
2. Transmitter control (TX) board
3. Panel A
*TX B FAIL
1. Panel B cables and connectors
2. TX board
3. Panel B
NO SLAVE
1. Verify connections to slave unit
OUTPUT
2. Verify TX board
SLAVE
1. Verify connections from master unit
SYNC
2. Verify TX board
SYNC
1. Power connections to TX board
FAIL
2. Power supply module
3. Transmitter control board
AC SYNC FAIL
1. Make sure AC power is connected
Ensure line voltage is
between 100 and 240 VAC.
TX OPTIC FAIL
1. Make sure panel cables and PC Board
are plugged in
2. IR Emitter board assembly in panel A
Содержание PD 6500i