GARRETT PD 6500

i

USER MANUAL

3.5.22

ALTER ADMNISTRATOR CODE 

(+ TO ALTER CODE 2)

The Administrator Adjustments code (referred to as CODE2) is factory preset
to 5678. To change it:

1. Press the + touchpad.
2. Enter a new four-digit code.
3. When the LCD prompts, REPEAT CODE, re-enter the new four-digit 

code. The message, CODE ENTERED OK, should appear. (If the 
message, INVALID ENTRY, appears, repeat steps 2 and 3.)

Press ACCESS for the next adjustment or OPERATE to resume normal 
operation.

3.6

CODE RESET

Should the administrator access code be forgotten or misplaced, the PD 6500

i

has a mechanical method for resetting the administrator access code to 
factory preset code.

1.

Open the main cover of the detection unit.

2.

Remove the three screws attached to the controller module cover.

3.

With power turned on and the unit in Operate mode, press and hold the 

ACCESS CODE RESET button (on the upper left side of the lower circuit 
board) for ten seconds. (See Figure 3-2)

FIGURE 3-2

Содержание PD 6500i

Страница 1: ...tors Garrett Metal Detectors 1881 West State Street 1881 West State Street Garland Texas 75042 6797 USA Garland Texas 75042 6797 USA Phone 800 234 6151 Phone 972 494 6151 Fax 972 494 1881 Fax 972 494...

Страница 2: ......

Страница 3: ...ce the PD 6500i in an area where it is protected from direct rain mist and or condensation and position it on a level stable floor free from vibration CAUTION PD 6500i may be firmly anchored to the fl...

Страница 4: ...MENT PROCEDURE 19 2 4 MULTIPLE WALK THROUGH SITE INSTALLATION SETUP 20 3 MENUS 22 3 1 MENU TABLE 23 3 2 POWER ON OFF 24 3 3 SELF TEST 24 3 4 USER ACCESS 24 3 5 MENU ITEMS 24 3 6 CODE RESET 33 4 PROGRA...

Страница 5: ...detection of the Sensitivity smallest of metallic targets regardless of shape and orientation Traffic Pacing lights with international wait and proceed symbols are Flow located on the entrance side o...

Страница 6: ...continue the assurance of Garrett products safety Any recommendations or directives issued by personal physicians should be followed If for any reason e g doctor s orders etc a patron objects to bein...

Страница 7: ...omputer Magnetic Storage Media Canada Health and Welfare Performance Standards Walk Through RPS SC 18 section 3 2 2 which addresses the issue of electromagnetic effects to cardiac pacemakers Occupatio...

Страница 8: ...mprised of a series of lights The bar graph light activity represents the level of metal detection intensity occurring within the archway The detection intensity is dependent upon the quantity and com...

Страница 9: ...setting See section 3 1 FIGURE 1 2 1 3 1 6 1 OPERATE ON SELF TEST The OPERATE touchpad is used to turn the PD 6500i on The unit will be ready to operate within ten seconds Activate the manual self tes...

Страница 10: ...provide information about 11 horizontal and 3 vertical positions for a total of 33 pinpoint areas These lights help the operator to identify the precise location of a metal object within the walk thr...

Страница 11: ...he entry of an access code for next level of security is required in order for operation to resume Each access attempt is indicated by an increase in the sequence code as reported on the LCD Any unaut...

Страница 12: ...is recommended that cords be secured to the ground using highly visible industrial tape or cable trays This ensures that the cord is visible to patron traffic and prevents personal injury as well as...

Страница 13: ...the flow of traffic through a checkpoint and can be troublesome when trying to operate within time constraints If a site is too big it becomes difficult to oversee the checkpoint and valuable space is...

Страница 14: ...GARRETT PD 6500i USER MANUAL 14 2003 GARRETT METAL DETECTORS PN 1532010 REV A ONE LINE CONFIGURATION 40 x20 TENT...

Страница 15: ...15 2003 GARRETT METAL DETECTORS PN 1532010 REV A GARRETT PD 6500i USER MANUAL TWO LINE CONFIGURATION 40 x40 TENT...

Страница 16: ...tables and personnel should be placed a minimum of 6 from the detector X Ray machines and other complementary screening equipment should be placed a minimum distance of 12 from the detector 2 2 UNIT...

Страница 17: ...panels A and B using four screws and finishing washers Do not tighten FIGURE 2 2 4 Open the door of the detection unit Select a panel for power use keeping in mind the location of the electrical outle...

Страница 18: ...e detection unit 6 Use the four remaining screws and washers to attach the crosspiece to the two panels as shown in Figure 2 4 FIGURE 2 4 7 If optional stabilizer mounts are to be used attach stabiliz...

Страница 19: ...prevent rocking DO NOT over tighten As an option stabilizer bases or adhesive floor mounting plates are available for securing the PD 6500i to the floor without drilling 2 3 PLACEMENT PROCEDURE 1 Pla...

Страница 20: ...PD 6500i must be free from interference from adjoining walk through metal detectors To ensure that there is no interference observe the bar graph of one walk through while switching the remaining walk...

Страница 21: ...eries of PD 6500i s synchronization to MASTER CHANNEL 1 and make sure it is always connected to either AC power or battery power 8 Set all other units synchronize to SLAVE 9 Set the remaining units to...

Страница 22: ...rough These Monitor Functions may be viewed by the Operator without a user login The Administrator however has the authority to turn these Monitor Functions ON or OFF for the operator Supervisor This...

Страница 23: ...View Volume 0 12 0 12 0 12 Patron Count View View View Alarm Count View View View Alarm View View View Sequence View View View Reset Counters Yes Yes Yes Preferences Tone 1 9 Pacing Lights On Off Zone...

Страница 24: ...in The unit will initiate a self test that will report the results on the LCD screen Should the self test reveal a problem a failure message will appear e g SYNC FAIL Refer to Table 5 4 for a list of...

Страница 25: ...user is authorized to change the base sensitivity the user may scroll from 1 200 using the touchpads To determine proper sensitivity setting follow ALARM LEVEL setting instructions in section 3 5 18...

Страница 26: ...l operation 3 5 8 RESET COUNTER RESET COUNT will appear on LCD For Operator Access Level user to reset counter the Administrator must have the Operator Enable set to ON position Supervisor and Adminis...

Страница 27: ...me the user may use the touchpads to adjust the time between 1 SEC to 4 SEC in 1 second increments Press ACCESS for the next adjustment or OPERATE to resume normal operation 3 5 13 IR ANALYSIS An infr...

Страница 28: ...he receiving antennas Any number less than 50 is acceptable A number greater than 50 will elicit the message RX BAL and the pinpoint lights within the problem zone will illuminate Should this occur en...

Страница 29: ...B 3 5 18 ALARM LEVEL Alarm level is a tool that helps you determine the lowest level of sensitivity required to activate an alarm for a particular metal object This information can then be used to det...

Страница 30: ...rease or to decrease in 1 increments the percent to be increased or decreased from the base sensitivity level The following are a few examples of adjustments based on a base sensitivity setting of 150...

Страница 31: ...31 2003 GARRETT METAL DETECTORS PN 1532010 REV A GARRETT PD 6500i USER MANUAL FIGURE 3 1...

Страница 32: ...g choice of 63 to 192 will appear on LCD If user is authorized to change this setting the user may use the to increase or to decrease in 1 increments the percent to be increased or decreased from the...

Страница 33: ...NVALID ENTRY appears repeat steps 2 and 3 Press ACCESS for the next adjustment or OPERATE to resume normal operation 3 6 CODE RESET Should the administrator access code be forgotten or misplaced the P...

Страница 34: ...to detect all metals and provide the highest level of security available Exceeds FAA and TSA detection requirements Provides no discrimination against innocuous items and is therefore recommended for...

Страница 35: ...ARRANTIES EXPRESSED OR IMPLIED INCLUDING THE WARRANTY OF MER CHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THE BUYER ACKNOWLEDGES THAT ANY ORAL STATEMENTS ABOUT THE MERCHANDISE DESCRIBED IN THIS CO...

Страница 36: ...head panel contains all of the circuit boards required for operation The cables that connect the controller module to the side panels are plugged into connectors at the top of each panel The controlle...

Страница 37: ...37 2003 GARRETT METAL DETECTORS PN 1532010 REV A GARRETT PD 6500i USER MANUAL FIGURE 5 3 22 10 9 FIGURE 5 2 FIGURE 5 4...

Страница 38: ...ht Bar Controller 2341100 2 12 Light Bar Slave Set 2341200 2 13 Power Supply Module With Cover 2338602 1 14 Touchpanel 9425100 1 15 Speaker Assembly 2404900 1 16 Cable Assembly A Det Unit Short 242100...

Страница 39: ...AVE OUTPUT POWER MOD FAIL SLAVE SYNC RX BOARD FAIL AC SYNC or SYNC FAIL RX A or B ZN PK FAIL RX or TX OPTIC FAIL CABLE MISCONNECT RX A or B ZN BAL FAIL DSP FAIL TABLE 5 4 Self Test Possible Failures a...

Страница 40: ...ove zone with balance failure object or relocate PD 6500i RXB Zn BAL 1 Cable and connectors to panel B Ensure no large metal object FAIL 2 Circuit Board Connection nearby If necessary move zone with b...

Страница 41: ...three screws that hold the controller module cover 4 Remove the four acorn nuts from the package 5 Install the battery pack module with the acorn nuts 6 Disconnect the power supply module connector f...

Страница 42: ...3 external logic control see Figures 6 3 6 4 and 6 5 show alternatives to connecting an external device that requires a direct low voltage current The output is an open collector configuration that c...

Страница 43: ...d to either side of the base of the unit This connection is made with an IEC rated connection that allows easy removal of the unit for maintenance emergency etc If a more secure attachment of the powe...

Страница 44: ...2003 GARRETT METAL DETECTORS PN 1532010 REV A Copyright 2003 Garrett Metal Detectors All Rights Reserved 1532010 REV A...

Отзывы: