33
©2003 GARRETT METAL DETECTORS
PN 1532010 REV A
GARRETT PD 6500
i
USER MANUAL
3.5.22
ALTER ADMNISTRATOR CODE
(+ TO ALTER CODE 2)
The Administrator Adjustments code (referred to as CODE2) is factory preset
to 5678. To change it:
1. Press the + touchpad.
2. Enter a new four-digit code.
3. When the LCD prompts, REPEAT CODE, re-enter the new four-digit
code. The message, CODE ENTERED OK, should appear. (If the
message, INVALID ENTRY, appears, repeat steps 2 and 3.)
Press ACCESS for the next adjustment or OPERATE to resume normal
operation.
3.6
CODE RESET
Should the administrator access code be forgotten or misplaced, the PD 6500
i
has a mechanical method for resetting the administrator access code to
factory preset code.
1.
Open the main cover of the detection unit.
2.
Remove the three screws attached to the controller module cover.
3.
With power turned on and the unit in Operate mode, press and hold the
ACCESS CODE RESET button (on the upper left side of the lower circuit
board) for ten seconds. (See Figure 3-2)
FIGURE 3-2