background image

HD-3WXL Operation and Installation Manual 

 

 
 

HD-3WXL Series 

Continuous Degaussing System 

 

Operation and Installation Manual 

 

     

 

 

 

 

 

www.Garner-Products.com

 

 

(800) 624-1903 

10620 Industrial Ave., Suite 100 

Roseville, CA  95678  

 

Manufactured in the U.S.A.  

PN 4075-244 Rev H 

 

 

Содержание HD-3WXL Series

Страница 1: ...stallation Manual HD 3WXL Series Continuous Degaussing System Operation and Installation Manual www Garner Products com 800 624 1903 10620 Industrial Ave Suite 100 Roseville CA 95678 Manufactured in the U S A PN 4075 244 Rev H ...

Страница 2: ...n 4 Power Plug 7 Fuse Block 7 Placement 7 Cooling 7 OPERATION 8 Controls and Indicators 8 POWER Button ON Indicator Yellow 8 LCD Display 8 Degaussing Instructions 8 Automatic Degaussing 8 Powering Up 8 Automatic Degaussing Steps 9 Automatic Degaussing Technical Detail 10 Degaussing Instructions for DLT Media 11 Error Codes 12 Charge Error 12 Door Open Error 12 Gauss Error 12 Overheat Error 12 Ejec...

Страница 3: ...HD 3WXL Operation and Installation Manual 1 DECLARATION OF CONFORMITY ...

Страница 4: ...oercivity media while also limiting the magnetic field exposure to 1 second for every 20 pieces of media degaussed Distance from side of degausser Magnetic field 0 0cm Duration of Field 61 gauss 0 05 Second 6 15cm 6 gauss 0 05 Second 12 30cm 2 gauss 0 05 Second Note The testing room measured 0 4 gauss before degausser was plugged in Average Operational Distance AOD from user to the HD 3WXL is 12 1...

Страница 5: ...harging 4 0A At the time of ERASE 0 3A Degausser System Capacitive Discharge Operating Time Duty Cycle Continuous Erasing time 10 milliseconds Cycle time 9 seconds per cycle Magnetic Field 10 000 Oe Peak 9 200 Oe measured in center Max Media Size 6 75 in 171mm W x 4 5 in 114mm H x 1 8 in 45 7mm D Erasing Area Size 6 75 in 171mm W x 4 5 in 114mm H x 1 8 in 45 7mm D Media 2 5 type HDD 3 5 type HDD D...

Страница 6: ... this manual INSPECTION POWER REQUIREMENTS INSTALLATION Check the power specifications label located on the back of the degausser It is important to ensure the correct power is applied to the degausser Call Garner Products Inc if the voltage listed is not compatible with your voltage International customers call 011 916 784 0200 Input Voltage Configuration The HD 3WXL model is equipped with a volt...

Страница 7: ...ollow the steps listed below 1 Read the Warning labels on the preceding page and on the HD 3WXL 2 Remove the power cord from the back of the HD 3WXL 3 Confirm and note the outlet voltage the HD 3WXL will plug into 4 Loosen the 4 screws from the Voltage Selection Panel and remove the Voltage Selection Panel ...

Страница 8: ... Panel confirm the correct jumper setting for the outlet voltage noted in Step 3 6 To change the jumper position pull the brown jumper wire from terminal on the upper side of the fuse block and move it to the corresponding terminal that matches your outlet voltage This photo shows the correct jumper setting for 120 VAC ...

Страница 9: ...he same voltage range can be used as spares Placement The degausser must be placed on a flat hard surface with a minimum 6 inch 15cm space from any object that may interfere with the cooling fan exhaust located on the backside of the degausser As a general rule media not intending to be erased should be kept at least 2 ft 60cm away from the degausser Cooling Forced air cooling is used to maintain ...

Страница 10: ...splay gives status automatic count total count software version field strength user instructions and fault messages DEGAUSSING INSTRUCTIONS The HD 3WXL media degausser operates automatically when media is inserted into the media door Automatic Degaussing Sensors built into the Media Entrance Door sense that a hard drive has been inserted The act of depositing media through the Media Entrance Door ...

Страница 11: ...splays Degausser Model FIRMWARE VER Displays current firmware version TOTAL Displays total erasing cycles Number on left indicates number of times the counter reached 50 000 Insert Media Session 0 Ready for media to be placed in the Media Entrance Door Counter for erase cycles from power up Step 3 Insert media Door Open Indicates Media Entrance Door is open this is normal when inserting media to b...

Страница 12: ...ld The portion of the graph represents the normal range for field strength level The I within the indicates where the erasing field strength measured The position of the I can vary from cycle to cycle as it is based on the actual field strength 6 If the field is in the normal range the LCD will display DATA ELIMINATED 7 If the field is not in the normal range the LCD will display ERASE FAILURE As ...

Страница 13: ...re Note For DLT media that is to be re used Although the data is completely degaussed in one operation a second pass rotated at 90 degrees is required to smooth out any magnetic fluctuation Note If the second pass is not completed the tape drive may eject the tape and indicate that the tape needs cleaning Performing a second pass of the DLT through the HD 3WXL at 90 degrees will correct this condi...

Страница 14: ...ror indicates the erasing field may not have been adequate to effectively erase the media in the degaussing chamber Media will not be ejected Action Turn off the HD 3WXL for approximately one minute Turning off the power to the HD 3WXL will clear the error Turn the HD3 WXL back on To initiate the degauss cycle with media already in the degaussing chamber push the Media Entrance Door open and let i...

Страница 15: ... 244F Manual operation HD 3WXL 4300 006 Fuse 15A 250V 4300 022 Fuse 7 5A 250V 4700 043 Surge Resistor 4800 009 SCR Module 4800 012 Zener Diode 160V 50W 4800 017 Blocking Diode 5100 035 Switch PB Ilum Red on mom 5100 037 Switch PB Ilum Yellow on off 5100 036 Switch PB Ilum Green on mom 5600 022 Transformer toroidal SA1400 219G Media Transport Assy HD 3WXL SA1400 221G Assy front panel chassis SA1400...

Страница 16: ... REPLACEMENT SERVICE AS DETERMINED BY GARNER IN ITS SOLE DISCRETION No Garner dealer reseller agent or employee is authorized to make any modification extension or addition to this warranty If any term is held to be illegal or unenforceable the legality or enforceability of the remaining terms shall not be affected or impaired EXCEPT AS PROVIDED IN THIS WARRANTY AND TO THE EXTENT PERMITTED BY LAW ...