Page A-16
G300 Installation Manual – Pinouts
Revision A
190-00921-01
A.3.9
Frequency Counter Inputs
Digital signals are updated to the display at a rate of 10 times per second (10 Hz). Digital inputs are low
when the signal is
≤
2 Vdc or the resistance to ground is
≤
375
Ω
, and high when the signal is > 3.5 Vdc
or the resistance to ground is > 100 k
Ω
. Digital inputs can also be configured as discrete inputs.
Pin Connector
Pin
Name
I/O
17
P732
FREQUENCY COUNTER IN* 1
IN
19
P732
FREQUENCY COUNTER IN* 2
IN
36 P732
FREQUENCY COUNTER IN* 3
IN
38
P732
FREQUENCY COUNTER IN* 4
IN
* Indicates Active Low
The following table lists the minimum frequency, maximum frequency, and duty cycles for each of these
inputs.
Pin Name
Minimum Frequency
Maximum Frequency
Duty
Cycle
FREQUENCY COUNTER IN* 1
1 Hz
950 Hz
50%
FREQUENCY COUNTER IN* 2
1 Hz
100 KHz
50%
FREQUENCY COUNTER IN* 3
1 Hz
100 KHz
50%
FREQUENCY COUNTER IN* 4
1 Hz
100 KHz
50%
A.3.10
Fuel Select Outputs
Pin Connector
Pin
Name
I/O
76 P732
RESERVED (FUEL SENSOR PULL-UP 2
(ANALOG IN 15))
OUT
77 P732
RESERVED (FUEL SENSOR PULL-UP 1
(ANALOG IN 14))
OUT
Содержание GMU 44
Страница 1: ...190 00921 01 March 2009 Revision A G300 Installation Manual ...
Страница 36: ...Page 4 8 G300 Installation Manual GSU 73 Revision A 190 00921 01 This page intentionally left blank ...
Страница 44: ...Page 6 4 G300 Installation Manual Antennas Revision A 190 00921 01 This page intentionally left blank ...
Страница 94: ...Page 10 12 G300 Installation Manual Troubleshooting Revision A 190 00921 01 This page intentionally left blank ...