Consideration for Wing Grounded Lighting Fixtures
The following installation practices are recommended if the required GMU 44 mounting bracket is
located in the wing.
1.
The wing tip lights should not have a power ground referenced to the chassis of the light
assembly that would then be referenced back to the airframe ground via the light assembly
mounting.
2.
A dedicated power ground should be used and returned as a twisted pair with the power source
back into the fuselage for a wing mounted GMU 44.
These installation practices will prevent magnetically interfering currents from flowing in the wing skin
that encloses the GMU 44. Electrically isolating the light assembly should not be used as an alternative to
item 1 above, unless the isolated light assembly has been analyzed for adequate protection against direct
attachment of lighting.