Part # P153 (11/06)
Page 18
4. Carefully remove the dial, not disturbing the shaft
position
5. Hold the shaft steady and with a small flat screw
driver turn the calibration screw located inside
the shaft clockwise to decrease temperature and
MAINTENANCE AND CLEANING Continued
counter clockwise to increase temperature. NOTE:
Each ¼ turn of the screw will create a change of
approximately 35° F (20°C).
6. Replace the thermostat dial and repeat steps 1
through 3 verify that a correct adjustment has been
made.
It is essential that the instructions in this booklet are
strictly followed for the safe and economical operation
of the equipment. If it is know or suspected that a fault
exists on the appliance then it must not be used until the
fault has been rectified by a competent person.
SAFETY