Part # P153 (11/06)
Page 10
Installation Of Range Mount Salamander
1. The rear of the range must be easily accessible.
2. Place the salamander in position on the range.
Slide the uprights into the opening at the oven rear.
Secure the salamander uprights to the range with
the hex head bolts provided.
3. Remove the terminal block access cover
4. Pass the wires though cable entrance hole.
5. Secure the cable connector
6. Terminate the salamander wire at the terminal
block provided (Red to L1, Black to L2 or N, Green
to GRN or E).
NOTE: When mounting a salamander over an existing
range in the field, an independent fussed connection
must be made though the knock out plate provided in
the main back of the salamander.
Assembly of Backguard/High Shelf
The back guard or high shelf will have been shipped
separately. To install, put the backguard/high self on the
rear of the range, slipping the uprights into the opening
on each burner box side. Fasten the upright to the burner
box side with four hex fasteners provided.
Code Requirements
The Garland S/SS680 series complies with the standards
CSA C22.2 no.109 – latest edition, the UL197 – latest
edition and the NSF#4 – latest edition. The installation
and connection of this appliance must comply with
current codes. In Canada – The Canadian Electrical
Code Part 1 and in the USA – The National Electrical
Code.
The Garland SU680 series complies with the essential
requirements of the Directives 73/23/EEC, 89/336/EEC,
89/392/EEC, 93/68/EEC and the standards, EN60335,
IEC801.2, IEC801.3, IEC801.4, IEC801.5, IEC801.6 and
IEC801.11.
INSTALLATION Continued
Electrical Supply
Before attempting the electrical connection, the
rating plate should be checked to ensure that the
equipment’s electrical characteristics and supply electrical
characteristics agree. On ranges and salamanders the
supply entrance is located at the rear or alternatively on
the main bottom. The supply terminal block is accessible
from the front. The electrical supply must be adequate
for the voltage, phase, and current marked on the rating
plate.
NOTE: A means of disconnection from the supply
having a contact separation of at least 3 mm in all poles
must be incorporated in the fixed wiring.
This equipment is intended to be installed with fixed
permanent wiring.
WARNING: This appliance must be grounded.
Single And Three Phase Connection
Unless otherwise noted, all ranges are shipped from the
factory for three phase connection. Salamanders are
shipped from the factory for single phase connection. A
wiring diagram is attached to the rear of each appliance.
Visually check all electrical connections. The range is
wired at the factory as specified on the order. If it is
necessary to change the phasing refer to the wiring
diagram.
Commissioning
Ensure all circuit breakers located in the lower
compartment are set to the ON (1) position
1. Ensure that all controls are in the OFF position and
turn on the main electrical supply
2. Operate each section of the range or salamander
in accordance with the instructions given in the
Operating Instructions
3. Check that the product functions correctly and
that the voltage supply to the unit does not drop
more than 5% when all sections are operated
simultaneously.