8

2.  After selecting the proper smoke alarm location 

as described on Page 2, attach the mounting 

bracket to the ceiling as shown in 

Figure 2A

. For 

wall mounting see 

Figure 3A

. Place the mounting 

plate on the wall; be sure the “A” line is horizontal (parallel to the floor). Use 

the screws and cavity fixings provided to secure the mounting bracket (use 

3/16” drill bit for cavity fixings.).

3.  This alarm has a battery permanently sealed inside the alarm. 

No battery installation or maintenance is necessary.

Note:

 

Extensive cycling between high and low temperatures will significantly reduce 

battery life. Long term exposure to high temperatures will degrade the battery 

over time. Fire Knight recommends locating this alarm in a controlled temperature 

environment (20-30°C) for optimum life.

ACTIVATING THE ALARM

Once activated, the battery will supply power to the alarm or the life of the alarm 

(10 years). Ensure that the mounting bracket is mounted correctly before installing 

the alarm on he mounting bracket.
2.  To activate the alarm, install the alarm on the mounting bracket (

Figure 3C

and rotate the alarm clockwise (as indicated on the alarm cover) until the 

alarm snaps into place.

The alarm is now activated!

WARNING:

 Alarm will not operate if it is not fixed on mounting plate.

3.  After installation/activation, test your alarm by depressing and holding down 

the Test button for a minimum of 1 second (or until the alarm sounds). 

This should sound the alarm. The alarm will sound at a low level to avoid 

discomfort. If the Test button is pressed for greater than 5 seconds, the 

alarm will sound at the full 85 decibels and may cause some discomfort.

1.  To ensure aesthetic alignment of the 

alarm with the hallway or wall, the 

“A” line on the mounting bracket 

should be parallel with the hallway 

when ceiling mounting or horizontal 

when wall mounting.

Figure 3C

Installation Instructions

Содержание Ongard OG1400

Страница 1: ...against fast flaming fires and slow smouldering fires both ionisation and photoelectric alarms should be installed 09 18 ATTENTION Please take a few minutes to thoroughly read this user guide which sh...

Страница 2: ...of your family s home safety plan You can trust Garland OnGard to provide the highest quality safety products Please take a few minutes to thoroughly read this user guide and save it for future refere...

Страница 3: ...protection see Figure 1C Things to Consider For Ceiling Mounting Smoke from a fire will rise to the ceiling and spread horizontally Mounting the smoke alarm in the centre of the ceiling places it clos...

Страница 4: ...Protection KITCHEN BEDROOM BEDROOM BEDROOM LIVING ROOM KITCHEN BEDROOM BEDROOM HALL BASEMENT FIGURE 6 1 A FIGURE 6 1 B FIGURE 6 1 C SINGLE FLOOR PLAN MULTIPLE FLOOR PLAN BEDROOM FAMILY ROOM WORKSHOP B...

Страница 5: ...G 300mm MINIMUM 600mm MINIMUM MAXIMUM SIDE WALL BEST PLACEMENT DO NOT INSTALL DO NOT INSTALL DEAD AIR NOT IN THIS AREA ANYWHERE IN THIS AREA 500mm 1000mm DEAD AIR ACCEPTABLE PLACEMENT 100mm Installati...

Страница 6: ...stall the smoke alarm on an inside wall with the top edge of the alarm at a minimum of 10cm and a maximum of 30cm below the ceiling Figure 2A For minimum protection install at least one alarm close to...

Страница 7: ...0 C or hotter than 40 C Do not install in areas where the relative humidity RH is greater than 93 If a kitchen alarm is desired it should have an alarm silencer feature or be a photoelectric type Do...

Страница 8: ...pply power to the alarm or the life of the alarm 10 years Ensure that the mounting bracket is mounted correctly before installing the alarm on he mounting bracket 2 To activate the alarm install the a...

Страница 9: ...he mounting plate With the blocks removed the tamper resist feature will be activated when the alarm is installed on the mounting plate The tamper resist tab will have to be released in order to remov...

Страница 10: ...om your alarm may indicate a defective alarm and it should be returned for service OPERATION The smoke alarm is operating once the alarm is activated see Activating the Alarm and testing is complete W...

Страница 11: ...e LED will flash every 0 5 seconds when the alarm is sounding The flashing LED and pulsating alarm will continue until the air is cleared The LED will flash every 10 seconds while in Hush mode The LED...

Страница 12: ...and call the fire service If no fire is present check to see if one of the reasons listed on the Installation section To minimise nuisance alarms avoid these locations may have caused the alarm WARNI...

Страница 13: ...ng unsociable hours CLEANING YOUR ALARM YOUR ALARM SHOULD BE VACUUMED ONCE A MONTH If the tamper resist feature has been activated you will need to follow the instructions on Page 8 to remove your ala...

Страница 14: ...powered alarms without battery backup will not operate if the AC power has been cut off such as by an electrical fire or an open fuse Smoke alarms must be tested regularly to make sure the batteries...

Страница 15: ...two family dwelling units Outside of each separate sleeping area in immediate vicinity of the sleeping rooms On each level of the dwelling unit including basements Exception In existing one and two f...

Страница 16: ...fore an emergency You may not be able to reach your children It is important they know what to do What to do when the Alarm Sounds Alert small children in the home Leave immediately by your escape pla...

Страница 17: ...the ACL 5 1 Garland s Products come within guarantees that cannot be excluded under the ACL 5 2 The Customer is entitled to a replacement or refund for major failure and for compensation for other re...

Страница 18: ...y Period you are entitled to submit a warranty claim by first visiting the Garland website address below and filling out the Return Form On contacting Garland and providing the proof of purchase The o...

Отзывы: