Dimensions and Technical Specifications 

 

RTCSmp Built-In Temperature Controlled Hold-Line 

 
 

Part # 4532287  Rev 2 (1/20/14) 

 

3

 

Dimensions and Technical Specifications 

3.1

 

Rating Plate  

The rating plate specifies important information such as model number, 
serial number, and electrical specifications. The rating plate is affixed to 
the bottom of the generator, by the connectors at the front. 

 

3.2

 

 Nomenclature and Models 

Series 

Built-In  Power (Watt) 

Voltage* (Volt)  Model 

HO 

= Hold Line

 

IN 

800    

(1 heat-retaining plate)

 

208 

HOIN800-208 

1600 

(2 heat-retaining plates)

 

HOIN1600-208 

2400 

(3 heat-retaining plates)

 

HOIN2400-208 

3200 

(4 heat-retaining plates)

 

HOIN3200-208 

* For the 230V-option, please consult your dealer for the availability in your region. 
 

3.3

 

Dimensions 

Component 

Dimensions 

Generator Housing 

11.93” x 12.28” x 5.31” (303 x 312 x 135 mm) 

Heat Retaining Plate 

20.47” x 12.60” x 2.95” (520 x 320 x 75 mm) 

Ceran Glass 

20.47” x 12.60” x 0.16” (520 x 320 x 4 mm) 

3.4

 

Electrical Specifications 

Model 

Voltage 

Power 

Power Per Heating Plate 

HOIN800/1600/2400/3200  208 V AC / 1Ph  

3200 W / 17A 

800W 

HOIN800/1600/2400/3200  230 V AC / 1Ph 

3200 W / 15A 

800W 

3.5

 

Operating Conditions 

Max. Tolerance of Nominal Supply Voltage 

+6 /-10 % 

Supply frequency 

50/60 Hz 

Ingress Protection class 

IP X0 

Minimal Diameter of Induction Pan 

5” (12cm) 

Maximum Ambient Temperature 

In Storage      > -4°F to +158°F (-20°C to +70°C) 
In Operation >+ 41°F to +104°F (+5°C to +40°C) 

Maximum Relative Air Humidity 

In Storage      > 10% to 90% 
In Operation > 30% to 90% 

Set Temperature Range 

122-212°F / 50-100°C 

Maximum air flow: 56.50cfm / 96m

3

 per hour and min. opening: 9.30 sq.in. / 6000mm

2

  is required. 

3.6

 

Compliances 

 

North American models

:

 

ETL listed in compliance with UL 197, CSA C22.2 No.109, NSF-4. Complies with FCC part 18, ICES-001 

 

CE models

 

comply with the latest European Norms:

 

EN 60335-1, EN 60335-2-36, EN 62233 (EMC/EMV) 

Содержание HOIN800

Страница 1: ...ES 001 WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFO...

Страница 2: ...NING SYMBOLS This symbol alerts you to a hazardous situation that WILL or COULD cause serious bodily harm or death Be alert and implement relevant safety precautions This dangerous voltage warning sym...

Страница 3: ...Dimensions RTCSmp HOIN800 1600 2400 3200 Heat Retaining Plate 9 4 4 1 2 Cut Out Dimensions 10 4 4 1 3 Parallel Installation and Clearance 10 4 4 1 4 Installation Steps 10 4 4 2 Control Unit Installati...

Страница 4: ...oundings and the induction unit Garland is not responsible for any damages or personal injury caused by failure to observe the safety requirements Risks involved when disregarding safety precautions m...

Страница 5: ...The induction suitable pans should also be in good condition without any uneven arched or partially detached bottoms 1 3 Improper Use of the Equipment The reliability of the induction unit can only be...

Страница 6: ...with a robust construction the RTCSmp Install Hold Line units are compact and powerful with the revolutionary RTCSmp Technology Realtime Temperature Control System with Multi Point sensing The RTCSmp...

Страница 7: ...3 x 312 x 135 mm Heat Retaining Plate 20 47 x 12 60 x 2 95 520 x 320 x 75 mm Ceran Glass 20 47 x 12 60 x 0 16 520 x 320 x 4 mm 3 4 Electrical Specifications Model Voltage Power Power Per Heating Plate...

Страница 8: ...unit must be installed securely in closed counters IMPORTANT Allow easy access to unit and cable connections for maintenance and service The heat retaining plate has to be mounted on a leveled and eve...

Страница 9: ...tion This will force hot air out the cabinet and away from the induction unit Consult an electrical or installation expert for the most appropriate location to install a cabinet exhaust fan 4 3 Config...

Страница 10: ...am in between units For other countertop materials the glass tops can be put side by side and the joints between glass tops must be water tight silicone sealed The Heat Retaining Plates can be install...

Страница 11: ...seal apply silicone adhesive completely around filling any gaps between the unit and the counter top surface Carefully wipe up the excess silicone 4 4 2 Control Unit Installation The induction unit co...

Страница 12: ...sures a proper grip on the knob To mount the control unit from the back of the panel 1 Drill holes on the panel using the dimensions provided 2 Remove the plastic knob from the control unit and attach...

Страница 13: ...ns A Horizontally with the exhaust fan facing down B Vertically with the connectors facing up 4 4 3 2 Mounting Methods To install use the holes A and or the mounting brackets C A There are two holes o...

Страница 14: ...low strictly the specifications on the rating plate The electrical connections must satisfy the national and local electrical codes If ground fault current protective switches are used they must be pr...

Страница 15: ...nes Zones B D B Within each zone there are two types of connectors i coil and ii sensor Use the coil cable to connect the coil connector on the Plate to the corresponding one on the Generator Similarl...

Страница 16: ...tween 122 212o F 50 100o C The digital Display underneath the Ceran glass shows the selected temperature with point eg Within 2 seconds the display shows the actual temperature and the point blinks Th...

Страница 17: ...en you heat up oil or grease check the cooking process frequently to prevent the oil or grease from overheating and burning BROIL DRY PROTECTION The RTCSmp electronic temperature control monitors over...

Страница 18: ...Plate of the RTCSmp HOIN800 1600 2400 3200 models is considered to be one heat zone Each heat zone is equipped with the latest RTCSmp sensor technology which enables temperature controls in realtime...

Страница 19: ...rol Switch s and Induction Generator are shown HOIN800 One switch controls one heat retaining plate HOIN1600 Two switches each controls only one heat retaining plate HOIN2400 Two switches one switch c...

Страница 20: ...ans when one plate is active and the temperature is shown with a blinking dot the other plates lay dormant with temperatures shown without dots This is normal However ensure you are using proper induc...

Страница 21: ...f any such residues IMPORTANT Air Intake Filter We recommend using an air intake filter in your installation see section 4 2 Ventilation A dirty blocked air intake filter can cause electronic damage t...

Страница 22: ...e all components relevant for safety are in perfect working order at all times Best Practice The induction unit is to be examined once a year by an authorized technician 9 Important Rules Six Simple r...

Страница 23: ...hot air to re enter the induction unit through the air intake slots Dirty air intake filter Empty pans are left on the cook top when the unit is ON Symptoms When a malfunction occurs the induction un...

Страница 24: ...ormal operating conditions Verify that no hot air is sucked in by the fan Reduce the ambient temperature The intake air temperature must be lower than 104 F 40 C Defective induction unit Ensure knob i...

Страница 25: ...ter wiring E06 Temperature inside the generator too high T 80 C 1 Check installation Airflow E10 Reduction KK temperature T 75 C 2 Check installation Airflow E12 Reduction internal temperature T 70 C...

Страница 26: ...Troubleshooting RTCSmp Built In Temperature Controlled Hold Line 26 Part 4532287 Rev 2 1 20 14 NOTES...

Страница 27: ...sed correctly you will help prevent potential harm to the environment or human health which could otherwise be caused by inappropriate waste handling of this product For more detailled information reg...

Страница 28: ...D LINE with RTCSmp TECHNOLOGY Garland Commercial Ranges Ltd 1177 Kamato Road Mississauga Ontario CANADA L4W 1X4 T 1 905 624 0260 F 1 905 624 5669 www garland group com USA Sales Parts and Service 1 80...

Отзывы: