INSTALLATION
Requirements of Installation
The underside and sides of the induction unit must be
absolutely clear of obstructions to provide for adequate
cooling air to enter and exhaust. Cooling air enters from the
bottom of the unit and is discharged either from the sides
(single or wok units) or from the rear (double units). An
air intake kit is provided to ensure adequate cooling air is
brought to the unit. A minimum of 30 sq inch opening must
be provided for the heated air to be discharged into the
room.
1
Make Sure that the induction unit does not take in hot
ambient air (concerns units standing side by side, or one
behind the other, or standing near a frying pan or oven).
2. The induction unit must not be placed near or on a hot
surface.
3. Make sure that the induction unit does not take in grease
laden air which is produced by other applications (deep
fat fryer, grill, frying pan). In which case you must use an
air an air duct (available as an accessory).
4. The air intake temperature must be under 104°F (40°).
5. The operating staff has to make sure that the installation,
support and inspection is done by qualified personnel.
Installation Ambience
CONDITIONS
STORAGE
FUNCTION
Max. Ambient
Temperature
> -4°F (-20ºC) to
158°F (70ºC)
> 41ºF (5ºC) to
104ºF (40ºC)
Max. Relative
Humidity Of Air
> -10% to 90%
> 30% to 90%
Electrical Connections
Turn the control knob to the OFF-position before connecting
the cooker to the voltage supply.
The operator has to insure that all installation, maintenance
and inspection work is carried out by authorized and
qualified personnel.
1. Check and ensure that the supply voltage matches the
voltage given on the specification plate.
2. The electrical connections must satisfy local house
installation regulations. The valid national and local
regulations must be observed.
3. The cooker is provided with a cord and plug (60 cycle
units only).
Cut Out Opening
Louvered
Air Exhaust
Opening
(By Installer)
Aluminum air duct
(Max 96" (8'))
mounted on collars
with hose clamps
Removable grease filter and air
intake housing mounted on
cabinet
Fresh Air Supply
Air Intake Housing
See Fig. # 1
Sleeve with hose clip:
mounted to cabinet
Sleeve with hose clip:
mounted on bottom of unit
Silicone
Содержание GIU 2.5 BI
Страница 2: ...Part 4520895 01 31 08 Page 2...
Страница 19: ...Part 4529895 01 31 08 Page 19...
Страница 20: ......
Страница 21: ...Pi ce n 4520895 01 31 08 Page 20...
Страница 39: ...Pi ce n 4520895 01 31 08 Page 2...