User Guide
EdgeLens | INT10G8XX56 | 4.22.1
1. Place the cursor on the Member option. Select with the left mouse button. Drag the Member
option to the entity box and release.
2. Select the Save option.
Taps Settings
The following configuration options may be displayed, modified, enabled or disabled.
No. Of Lost HB Packets
LFP
Heartbeats per Second
Reverse Bypass
Tap Modes
Bypass Threshold
Fail Mode
1. Select Settings.
The Configure Tap Settings panel will be displayed.
2. Enter the No. Of Lost HB Packets. Default is 10.
This is the number of heartbeats that must be lost on any inline appliance port member before
any entity will remove the inline appliance from the load balance group.
3. Enter the Heartbeats per Second. Default is 10.
This is the number of heartbeats per second sent on the inline appliance ports for all entities.
4. Select the Tap Mode.
Active
Allows the tap to automatically switch from inline to bypass if an issue occurs
with all entities A, B, C and D inline appliance port(s), loss of link or heartbeats
based on the bypass threshold value for each entity. Each entity A, B, C and D
are in bypass. The network port pairs 1-2, 3-4, 5-6 and 7-8 will be connected
together. When the issue with any entity A, B, C or D inline appliance port(s) is
resolved, have link and heartbeats, the tap will automatically switch back to
inline.
Figure 24 ATLB2 Chained Tap Mode (Inline)
Garland Technology | 716.242.8500 | www.garlandtechnology.com
Copyright © 2022 Garland Technology, LLC. All rights reserved.
44