User Guide
EdgeLens | INT10G8XX56 | 4.22.1
The Configure Heartbeat Settings panel will be displayed with the current configuration.
2. Enter the No. Of Lost HB Packets. Default is 10.
This is the number of heartbeats that must be lost on an inline appliance port before any
tap will remove the inline appliance from the load balance group.
3. Enter the Heartbeats per Second. Default is 10.
This is the number of heartbeats per second applied to the inline appliance ports for all taps.
4. Select Save to save updates.
5. Select Cancel to return the Bypass Taps panel.
Configure Load Balance Tap Mode
1. Edit the tap mode by placing the cursor on any tap and double-press the left mouse button.
The Tap panel will be displayed.
2. Place the cursor on the Load Balance Mode Select option. Select with the left mouse button.
Drag the Load Balance option to the blue box and release.
3. Select the red X to remove.
4. Place the cursor on the Inline Appliance option. Select with the left mouse button. Drag the Inline
Appliance option to the blue box and release. The next available vertical port pair will be added.
Repeat this step to apply up to four inline appliance ports per tap.
5. Select the red X to remove.
6. Select Save to save updates.
The Bypass Taps panel will be displayed. Inline will be displayed.
7. Place the cursor on the tap and double-press the left mouse button.
The Tap panel will be displayed. Green indicates Active.
8. Select Cancel to return the Bypass Taps panel.
Taps Settings
The following configuration options may be displayed, modified, enabled or disabled.
Tap Modes
Fail Mode
LFP
Reverse Bypass
Bypass Threshold
1. Edit the Tap Settings, by placing the cursor on any tap and double-press the left mouse button.
The Tap panel will be displayed.
Garland Technology | 716.242.8500 | www.garlandtechnology.com
Copyright © 2022 Garland Technology, LLC. All rights reserved.
38