User Guide
EdgeLens | INT10G8XX56 | 4.22.1
maintenance activities.
Figure 20 Load Balance Tap Mode (Force Bypass)
4. Select the Fail Mode.
Open
If selected, power is lost to the unit. The traffic will switch between the
network ports.
Closed
If selected, power is lost to the unit. The traffic will go down.
5. LFP
If enabled and link is lost on one of the network ports. The TX will be disabled on
the other network port. The RX for both network ports remain on.
Figure 21 Load Balance Tap Mode (LFP)
6. Reverse Bypass
If enabled and the inline appliance
port(s) fail, loss of link
or heartbeats, defined
by the bypass threshold value, 1-4. The TX will be disabled on both of the
network ports. The RX for both network ports remain on.
Figure 22 Load Balance Tap Mode (Reverse Bypass, Bypass Threshold=2)
Garland Technology | 716.242.8500 | www.garlandtechnology.com
Copyright © 2022 Garland Technology, LLC. All rights reserved.
40