35
10-sec increments.
3. Entry Delay time for Home Arm:
When Door Contact (DC) or PIR Detector (IR) is set as
Entry / Away Entry / Home
Access
attribute, the system gets into counting down period (Home entry timer) while
the DC or IR is triggered under Home / Day home / Night home arm mode.
During the counting down period, it is allowed to use correct PIN code to disarm the
alarm and the alarm reporting is not sent. On the other hand, if the correct PIN code
has not been entered during the period, Control Panel raises an alarm and sends
alarm report.
Options available are
Disable
(alarm immediately),
10 sec
,
20 sec
, up to
70 sec
in
10-sec increments.
4. Exit Delay time for Home Arm:
While the system gets into Home / Day Home / Night Home arm mode by Control
Panel, Remote controller (RC) or Remote keypad (KP), an Away exit timer starts
counting down.
During the counting down period, pressing the Home Button of the RC can restart the
counting. In addition, it is allowed to use correct PIN code or press Disarm Button of
the RC to stop the counting and return to disarm mode.
Options available are
Disable
(exit timer prohibited),
10 sec
,
20 sec
, up to
70 sec
in
10-sec increments.
5. Alarm
Length:
This is for you to select the built-in siren duration when an alarm is activated. Options
are
Disable
(no siren alarm), and
1-min
to
15-min
in 1-min increments.
z
If
Disable
is selected, when the Control Panel receives an alarm signal, the panel
siren and Bell Box (BX) will not raise an alarm sounding.
z
If BX’s alarm length is longer than the Control Panel’s, the system gives priority to
the Control Panel (e.g. when the BX’s alarm length is set as 3 mins, and the panel’s
alarm length is set as 1 min, both alarm siren stop at 1 min when an alarm is
triggered. However, the BX’s LED keeps flashing until 3 mins is expired.
6. Siren
Delay:
This is for you to decide how long should the Control Panel suppress the audible
alarms after a Burglar or Entry alarm is reported.
<
<
N
N
O
O
T
T
E
E
>
>
)
Some audible alarm will not be delayed (disregard its siren delay setting) when the
following conditions are detected:
9
Fire
9
Water
9
Personal panic
9
Medical emergency
9
Tamper
7. Mobility
Check:
This function is designed to avoid an accident (e.g. swoon or lost consciousness)
happening to the user without anyone notices. Under all modes except Away arm
mode, when the system does not detect any user movement within the pre-set mobility
period, an inactivity (fault) report will be sent to the monitoring center.