13-18-609 Page 18
2-6
Electrical Wire Routing
– Routing of the electrical power wires into the electrical hardware enclosure is
best done through its roof area.
Line Reactor –
A line reactor provides conditioning of the electrical power supply to the compressor
package by attenuating noise and fluctuations. It shall be required in your particular application if any of
the following conditions exist:
·
Transformer KVA is greater than recommended
– see Figure 2-3, page 18.
·
Line has switched Power Factor correction capacitors.
·
Existing line reactor not properly sized
– see Figure 2-3, page 18.
·
Other large loads on the same power feed as the compressor.
GD Model
Volts
VFD HP RATINGS
Max KVA
3% Line Reactor
GD Part Number
VS80
400/480
107
1000
90500142
VS80
575
107
1000
90500141
VS110
400/480
147
1500
90500144
VS110
575
147
1000
90500142
Figure 2- 3 – LINE REACTOR SIZING RECOMMENDATIONS
GROUNDING –
Equipment must be properly grounded in accordance with the National Electrical Code
and/or applicable local codes.
`
Failure to properly ground the compressor package could result in injury or death.
Install ground wiring in accordance with the National Electrical Code and any
applicable local codes.
MOTOR LUBRICATION
- Long time satisfactory operation of an electric motor depends in large measure
on proper lubrication of the bearings. Refer to Section 13, page 75 of this manual for complete motor
lubrication specifications and details.
Содержание VS80A
Страница 31: ...13 18 609 Page 30 4 5 Figure 4 2 PIPING AND INSTRUMENTATION ILLUSTRATION 300CGE797 A Ref Drawing...
Страница 33: ...13 18 609 Page 32 4 7 300CGE546 04 Ref Drawing Page 2 of 4...
Страница 34: ...13 18 609 Page 33 4 8 300CGE546 04 Ref Drawing Page 3 of 4...
Страница 35: ...13 18 609 Page 34 4 9 300CGE546 04 Ref Drawing Page 4 of 4...
Страница 37: ...13 18 609 Page 36 4 11 301CGE546 B Ref Drawing Page 2 of 4...
Страница 38: ...13 18 609 Page 37 4 12 301CGE546 B Ref Drawing Page 3 of 4...
Страница 39: ...13 18 609 Page 38 4 13 301CGE546 B Ref Drawing Page 4 of 4...
Страница 41: ...13 18 609 Page 40 4 15 302CGE546 05 Ref Drawing Page 2 of 4...
Страница 42: ...13 18 609 Page 41 4 16 302CGE546 05 Ref Drawing Page 3 of 4...
Страница 43: ...13 18 609 Page 42 4 17 302CGE546 05 Ref Drawing Page 4 of 4...
Страница 45: ...13 18 609 Page 44 4 19 303CGE546 B Ref Drawing Page 2 of 4...
Страница 46: ...13 18 609 Page 45 4 20 303CGE546 B Ref Drawing Page 3 of 4...
Страница 47: ...13 18 609 Page 46 4 21 303CGE546 B Ref Drawing Page 4 of 4...
Страница 70: ...13 18 609 Page 69 9 2 Figure 9 1 MINIMUM DISCHARGE PRESSURE CHECK VALVE...
Страница 86: ...NOTES...
Страница 87: ...NOTES...