![Gardner Denver Reavell 5236 Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/gardner-denver/reavell-5236/reavell-5236_operating-and-maintenance-manual_3868049033.webp)
P a g e
|
5
5236.MK2
COMPRESSOR
V14.0, En
2 LEADING PARTICULARS
2.1 UNIT DESIGNATION
Model ....................................................................................................................... C5236 Mk2
For Air compressors:
This compressor is designed for use compressing Air.
This compressor is NOT designed to compress any other gases.
2.2 TECHNICAL DATA
– GENERAL
Type ........................................................................... Four cylinder, 2 stage, vee configuration
Cooling .............................................................................................................................. Water
Direction of rotation, viewed from drive end ........................................................Anti-clockwise
Number of valves ........................................... One combined suction and delivery per cylinder
Type of valve ........................................................................................... Flat plate, standard lift
Mounting ...............................................................................Three point, anti-vibration mounts
2.3 TEMPERATURES
Minimum ambient temperature ............................................................................................. 0°C
Maximum ambient temperature........................................................................................... 45°C
Maximum ambient for radiator sets
(Contact Gardner
Denver Ltd for lubricant/duty restrictions) ......................................................................................
30/40°C
Maximum water inlet temperature ....................................................................................... 37°C
Temperature rise across machine ........................................................................... 10°C to 12°C
2.4 SPEEDS
Minimum speed ............................................................................................................. 750 rpm
Maximum speed .......................................................................................................... 1800 rpm
2.5 PRESSURES
Minimum working pressure .............................................................................................. 10 bar
Maximum working pressure ............................................................................................. 40 bar
Maximum inlet pressure ................................................................................................ 0.14 bar
Maximum water pressure ................................................................................................ 5.1 bar
Water jacket test pressure ............................................................................................ 10.3 bar
Oil pressure ............................................................................................................ 2 to 2.75 bar
Oil pressure (minimum worn compressor .......................................................................... 1 bar
2.6 INTERNAL DIMENSIONS
Piston stroke ................................................................................................................... 75 mm
First stage cylinder bore (2 off) ..................................................................................... 185 mm
Second stage cylinder bore (2 off) .................................................................................. 75 mm
2.7 LUBRICATION
Crankcase oil capacity ................................................................................................ 42.5 litres
Recommended oil
– Mineral .................................................................................. MYNTECK
– Synthetic ............................................................................ SYNTECK S
Recommended grease (for assembly) ............................................................. Shell Alvania R3
2.8 COOLING
Cooling water flow @ 15°C .......................................................................................... 75 l/h/kw
Содержание Reavell 5236
Страница 2: ......
Страница 3: ...AMENDMENTS ISSUE No DESCRIPTION DATE SECTION 1 NEW 09 10 2019 ALL 2 UPDATE GA VERSION B 15 04 2020 3...
Страница 4: ......
Страница 6: ......
Страница 7: ...Section 1 General Information...
Страница 8: ......
Страница 21: ...Section 2 Compressor...
Страница 22: ......
Страница 23: ...C5236 MK2 COMPRESSOR V14 0 En INSTALLATION OPERATION MAINTENANCE MANUAL C5236 MK2 WATER COOLED COMPRESSOR...
Страница 36: ...P a g e 8 INTENTIONALLY BLANK...
Страница 40: ...P a g e 12 INTENTIONALLY BLANK...
Страница 44: ...P a g e 16 INTENTIONALLY BLANK...
Страница 52: ...P a g e 24 INTENTIONALLY BLANK...
Страница 62: ...P a g e 34 INTENTIONALLY BLANK...
Страница 64: ...P a g e 36 INTENTIONALLY BLANK...
Страница 65: ...P a g e 37 5236 MK2 COMPRESSOR V14 0 En 10 APPENDIX...
Страница 67: ...REMARKS DATE REMARKS DATE...
Страница 71: ......
Страница 73: ...Section 3 Drawings...
Страница 74: ......
Страница 77: ......
Страница 78: ......
Страница 79: ...Section 4 Motor...
Страница 80: ......
Страница 86: ......
Страница 87: ...Section 5 Starter Control...
Страница 88: ......
Страница 95: ...Section 6 Equipment Data Sheets APPs...
Страница 96: ......
Страница 133: ......