Page 2 of 3
WIKA data sheet PV 34.82 ∙ 06/2017
Setting ranges, max. working pressure, measuring principle, hysteresis
Switch contacts
High-quality snap-action switch, self-cleaning
Switching function
Selectable: Normally open, normally closed, change-over
contact
Electrical rating
Current
utilization
1)
Voltage
Cur-
rent
Angular
connector
M 12 x 1,
cable
All
Resistive load
AC-12, DC 12
AC 250 V
AC 48 V
DC 24 V 4 A
Inductive load
AC-14, DC 14
AC 250 V
AC 48 V
DC 24 V 2 A
1) per DIN EN 60947-1
Electrical connection
Angular connector DIN 175301-803 A
Switching frequency
max. 100/min
Service life
> 2 x 10
6
switching cycles
Ingress protection
IP65 (IP67 with electrical connection M12 x 1
2)
or cable)
2) The stated ingress protection (per IEC/EN 60529) only applies when plugged in using
mating connectors that have the appropriate ingress protection.
Standard version
Case
Steel, galvanised
Reproducibility
±2 % of full scale value
Permissible temperature
Ambient: -20 … +80 °C
Medium: -20 … +80 °C
Process connection
Steel, galvanised
G 1/8, G 1/4, 1/8 NPT, 1/4 NPT, R 1/8 or M10 x 1
Measuring element
Diaphragm or piston with compression spring
Sealing
Diaphragm: NBR or EPDM
Piston: PTFE (dynamic) and NBR, EPDM or Viton
®
(static)
Viton
®
fluoroelastomer is a registered trademark of DuPont Performance Elastomers.
Setting
range
in bar
Max. working
pressure
in bar
Measuring
principle
Hysteresis
0,2 ... 2
60
Diaphragm
0,5 ... 8
1 ... 16
10 ... 30
350
Piston
10 ... 80
10 ... 160
20 ... 250
30 ... 320
40 ... 400
420
Example:
With a switch point
of 100 bar, a switch-
back difference
(hysteresis) of a
minimum 18 bar to a
maximum of 28 bar
can be set.
Example:
With a switch point
of 4 bar, a switch-
back difference
(hysteresis) of a
minimum 0.5 bar
to a maximum of
1.5 bar can be set.
Switch point in bar
Hy
ster
esis in bar
Hy
ster
esis in bar
Switch point in bar
GARDNER DENVER
APP457
Содержание Reavell 5236
Страница 2: ......
Страница 3: ...AMENDMENTS ISSUE No DESCRIPTION DATE SECTION 1 NEW 09 10 2019 ALL 2 UPDATE GA VERSION B 15 04 2020 3...
Страница 4: ......
Страница 6: ......
Страница 7: ...Section 1 General Information...
Страница 8: ......
Страница 21: ...Section 2 Compressor...
Страница 22: ......
Страница 23: ...C5236 MK2 COMPRESSOR V14 0 En INSTALLATION OPERATION MAINTENANCE MANUAL C5236 MK2 WATER COOLED COMPRESSOR...
Страница 36: ...P a g e 8 INTENTIONALLY BLANK...
Страница 40: ...P a g e 12 INTENTIONALLY BLANK...
Страница 44: ...P a g e 16 INTENTIONALLY BLANK...
Страница 52: ...P a g e 24 INTENTIONALLY BLANK...
Страница 62: ...P a g e 34 INTENTIONALLY BLANK...
Страница 64: ...P a g e 36 INTENTIONALLY BLANK...
Страница 65: ...P a g e 37 5236 MK2 COMPRESSOR V14 0 En 10 APPENDIX...
Страница 67: ...REMARKS DATE REMARKS DATE...
Страница 71: ......
Страница 73: ...Section 3 Drawings...
Страница 74: ......
Страница 77: ......
Страница 78: ......
Страница 79: ...Section 4 Motor...
Страница 80: ......
Страница 86: ......
Страница 87: ...Section 5 Starter Control...
Страница 88: ......
Страница 95: ...Section 6 Equipment Data Sheets APPs...
Страница 96: ......
Страница 133: ......