3–600    Page 3

For these smaller loads the lifting devices should be
fastened to the lifting attachments normally built into
the individual motor, engine, pump or transmission/
torque converter, or their separate support skids.

When lifting subassembled components, for example
a suction stabilizer attached to suction piping or a dis-
charge pulsation dampener attached to a strainer cross
and piping, use special lifting slings designed to safely
support the combined weight of the components.

If a crane or hoist is being used to lift large components
or assemblies, one or more persons should assist the
operator from the ground with guide lines attached to
the equipment being moved to properly position it and
prevent uncontrolled movement.

When you start to lift a pump, package unit, subassem-
blies or individual components and you observe the
equipment is tilting, or appears unbalanced, lower the
equipment and adjust the lifting device to eliminate
these improper lifting conditions before proceeding to
move the equipment.

It is poor practice and dangerous to allow the equip-
ment to pass over or close to your body or limbs.  Be
prepared to move quickly out of danger if equipment
starts to fall, slip or move unexpectedly toward you.

PRESSURIZED PUMP SYSTEMS

Fluids under high pressure can pos-
sess sufficient energy to cause per-
sonal injury, death and/or equipment
damage either through direct contact
with escaping fluid streams or by con-
tact with loose objects the pressur-
ized fluid propels.

Operating a pump against a blocked or restricted dis-
charge line can produce excessive pressures in the en-
tire discharge system, which can damage or burst dis-
charge system components.

Never operate a pump without a prop-
erly sized pressure relief valve lo-
cated in the flowing discharge line im-
mediately adjacent to the pump dis-
charge connection.

The relief valve should be placed in the flowing dis-
charge line and not at the opposite end of the discharge
manifold in a dead end connection.  The dead end may
become clogged with solid material carried in the fluid,
which could prevent proper relief valve operation.

Never place a shut–off valve or any
other component between the pump
discharge connection and the pres-
sure relief valve.

Make sure the pressure relief valve is installed so any
pressurized relief discharge from the valve is directed
away from possible contact with people or equipment.
The relief valve must be set to relieve at a pressure
equal to or below the maximum pressure values shown
on the pump data plate.  However, if a component is
used in the discharge system with a lower rated pres-
sure capability than that listed on the pump data plate,
the pressure relief valve must be set to relieve at a pres-
sure equal to or below the rated capability of the lowest
rated component.

Before starting the pump every time, check to in-
sure:

S

The pressure relief valve is in good operating
condition and has been set to the proper relief
pressure.

S

Any pipe line used to direct pressurized relief
flow to another location, such as a collecting
tank, is not blocked.

S

The discharge system is not blocked and all the
discharge line valves are open.

Check all fluid end discharge system components
including pipe, connections, elbows, threads, fas-
teners, hoses, etc., at least once every six months
to confirm their structural adequacy.
  With time,
wear, corrosion and fatigue can reduce the strength of
all components.  Magnetic iron and steel components
should be checked with magnetic particle or dye pene-
trant crack detection equipment.  Nonmagnetic materi-
als should be checked for cracks with dye penetrants.
All metallic components should also be visually
checked during these inspections for signs of corro-
sion.  If a component shows evidence of cracking or
loss of material due to corrosion it must be replaced
with a new part.

Continually monitor suction and discharge hose as-
semblies when the pump is operating for leakage, kink-
ing, abrasion, corrosion or any other signs of wear or
damage.

Содержание FXF - 5"

Страница 1: ...GARDNER DENVER DUPLEX POWER PUMP MODELS FXF 5 FXG 6 FXX 8 FXD 10 FXE 10 OPERATING AND SERVICE MANUAL 3 600 6th Edition June 1997...

Страница 2: ...ump Authorized distributor service technicians are factory trained and skilled in pump maintenance and repair They are ready to respond and assist you by providing fast expert maintenance and repair s...

Страница 3: ...sult in economical operation and minimum downtime Danger is used to indicate the presence of a hazard which will cause severe personal injury death or substantial property damage if the warning is ign...

Страница 4: ...on 3 12 Dimensions Running Clearances Section 4 15 TroubleShooting Section 5 19 Warranty Last Page List of Illustrations Figure 1 Crankcase Oil Requirements 7 Figure 2 Lubrication Fill Rate 8 Figure 3...

Страница 5: ...et or Suction Piping 7 Fluid Piston Rod Baffle 9 Fluid Piston Rod Packing 9 Fluid Pistons and Packing 8 Fluid Valves 10 Foreword ii Frame Oil Stop Head Packing 9 FXE Main Gear and Eccentric 13 Hammer...

Страница 6: ...TIONS SECTION 3 12 Service Abrasive High Pressure Pistons 9 Boiler Feed 8 Clean Oil or Petroleum Products 9 High Pressure Special Fluid 8 High Temperature 9 Low Pressure Water 8 Specifications Torque...

Страница 7: ...ions and instructions contained in these manuals If any of these documents are lost or become illegible they must be replaced immediately The danger no tices plus the operating and service manuals sho...

Страница 8: ...by trained experienced operators who are physically and mentally prepared to devote full attention and alert ness to the moving and lifting operations An operator should be fully aware of the use capa...

Страница 9: ...s charge line and not at the opposite end of the discharge manifold in a dead end connection The dead end may become clogged with solid material carried in the fluid which could prevent proper relief...

Страница 10: ...pump systems Block the crankshaft from turning and make certain that all pump drive motor or engine start switches or starter controls are clearly tagged with warnings not to start the pump while rep...

Страница 11: ...and all electrical components and wiring must meet the current National Electrical Code for explosive atmosp heres These precautions must be taken to avoid possible per sonal injury death and or equi...

Страница 12: ...r connect any equipment to the system which has a rated or tested pressure capability be low the system operating pressure The equipment must be shut down and the system pressure released before chang...

Страница 13: ...isable to use an am ple size discharge line to prevent excessive friction The use of an air chamber is recommended and ample size chambers are available for all pumps RELIEF VALVE Pump must be protect...

Страница 14: ...fittings A reliable multipurpose FIGURE 3 PACKING TYPE PISTON grease NLGI Grade No 2 should be supplied to these with discretion Roller bearings WILL HEAT IF TOO MUCH GREASE is used especially if bear...

Страница 15: ...is standard for water oil and general service Maxi mum service ratings for this packing are 250 PSI and 250_ F Molded convex packing is standard for mud service Maximum rated service temperature is 1...

Страница 16: ...ing approximately one thread of the locknut over the relieved portion of the rod as a protection to the threads FLUID VALVES Valves are easily installed in their in dividual valve pots Care should be...

Страница 17: ...3 600 Page 11 FIGURE 7 ROTATION OF ECCENTRIC PREFERRED ROTATION OF ECCENTRIC...

Страница 18: ...shings are pressed on the jackshaft and need not be removed unless replacement is necessary The jackshaft can be lifted clear of the gear teeth and removed The jackshaft is not interchangeable end for...

Страница 19: ...d wood block The bearing cone and seal sleeve on the side opposite the tapped hole will slip off the shaft To Install Main Bearings For All Pumps 1 Install eccentric with gear teeth in correct positio...

Страница 20: ...rom Gard ner Denver Machinery Inc OPERATING SPEEDS AND PRESSURES See bul letins for operating speeds and pressures for type of service All displacements are theoretical with piston rod vol ume deducte...

Страница 21: ...meter Diameter Stuffing Box End End Model Type Inches mm Inches mm Inches mm Inches mm FXF ALL 4 x 5 101 6 x 127 0 15 16 23 8125 1 3 4 44 45 2 1 16 52 3875 FXG ALL 5 x 6 127 0 x 152 4 1 25 4 1 13 16 4...

Страница 22: ...occurs b CONNECTING ROD LINER TO ECCENTRIC Actual 011 022 279 559 009 017 229 432 Feeler Gauge 010 021 254 533 008 016 203 406 Condemnable when liner knocks or clearance equals 040 1 016 035 889 c CR...

Страница 23: ...b CONNECTING ROD LINER TO ECCENTRIC Actual 007 015 178 381 006 014 152 356 Feeler Gauge 006 014 152 356 005 013 127 330 Condemnable when liner knocks or clearance equals 030 762 030 762 c CROSSHEAD P...

Страница 24: ...uid Cylinder 590 81 6 Head Stud Nut Fluid Cylinder Liner 25 3 5 25 3 5 25 3 5 25 3 5 Set Screw Suction Manifold to 260 36 0 Fluid Cylinder Discharge Manifold to 260 36 0 Fluid Cylinder Suction Manifol...

Страница 25: ...in drive c High back pressure d Piston rings in fluid end binding e Pistons improperly packed f Valves not holding g Leakage past fluid piston rings h Leakage past liner packing i Liners worn PUMP LO...

Страница 26: ...or shall be limited to the amount specified in the Company s labor rate schedule Labor costs in excess of the Company rate schedules caused by but not limited to location or inaccessibility of the equ...

Страница 27: ......

Отзывы: