Test the direction of rotation of the auxiliary ventilator
!
Only required for G-BH1 | G-BH9 with auxiliary ventilator (item. 0501, [
➙
15]).
1. Switch on the auxiliary ventilator briefly and then switch it off again.
2. Hold a sheet of paper in front of the air grille of the auxiliary ventilator
(item 0501, [
➙
15]).
The sheet is suctioned: direction of rotation is correct, no measures
The sheet is blown off: Direction of rotation incorrect, change direction of
rotation by interchanging two phases of electrical supply line
Sensors function check
Check that sensors (e.g. PTC resistor) are connected correctly.
Measure the acoustic emissions
!
It is necessary to measure the acoustic emissions for G-BH1 | G-BH9 without
piping, without silencers or without piping.
1. Ensure that all persons in the potentially excessive noise area wear ear pro-
tection.
2. Measure sound during operation.
3. If
necessary,
implement
sound protection measures (e.g. Reduction of oscilla-
tions and noises [
➙
21], provision of ear protection, identification of noise ar-
eas).
Measure oscillations
!
It is recommended to measure the oscillations for the prescribed operating
speeds.
1. Measure
oscillations.
2. If the permitted Speed of oscillation [
➙
41] is exceeded, provide measures for
Reduction of oscillations and noises [
➙
21].
7.4
7.5
7.6