6
Electric power connection
610.44434.40.000 · 08.2019
30
/
44
© Gardner Denver Deutschland GmbH
Integrated drive control by third party manufacturer
NOTICE
Mechanical damage!
In the G-BH1 | G-BH9, mounted drive controls from third-party manufactur-
ers can overload the foot and lifting attachment or damage the bearing due
to the oscillations.
Only mount drive controls from third-party manufacturers adjacently.
Connect wall-mounted drive control 2FC4
1. Open the junction box cover of the motor (item 0042, [
➙
14]).
2. Connect drive control
2FC4
(item 600w, [
➙
15]) according to the related op-
erating instructions [
➙
6].
3. Close the junction box cover.
Connect accompanying drive control from third party
manufacturer
When operating with drive controls from third-party manufacturers, observe:
▪
High-frequency current and voltage harmonics in the motor supply wiring can
cause electro-magnetic interference. This is dependent on the type of drive
control (type, manufacture, voltage supply measures).
▪
Observe the EMC notes of the drive control manufacturer.
▪
If necessary, use screened cables/wiring. To provide the optimum screening,
the screening must be connected to the metal junction box using a large-area
metal conducting fastener.
1. Open the junction box cover of the motor (item 0042, [
➙
14]).
2. Connect the drive control according to the circuit diagram in the junction box
cover and the manufacturer's operating instructions for the drive control.
3. Connect the PTC resistor according to the following examples.
4. Close the junction box cover.
K1
V1 U1 W1
2TP2
2TP1
M1
K1
K1
S1
S2
U1
L1 L2 L3
U V W
U2
L1
N
T1 T2
1K1
PE
PE
F2
F3
L1
L2
L3
N
PE
3~
M
Θ
Q1
I> I> I>
V1 U1 W1
2TP2
2TP1
M1
3~
M
Θ
A3
A2
A1
A1 PTC
resistor
A3 PTC resistor and evaluation unit
A2 Drive
control
6.4.2
6.4.3
6.4.4
Circuit diagram with
PTC resistor and eval-
uation unit