13-10-614 Page 63
Every Year
1.
Check the relief valve for proper operation. See Section 4.
2.
Check shutdowns for proper operation.
MAINTENANCE SCHEDULE
Maintenance Action
As Indicated by
AutoSentry
Controller
Every 8
Hours
Every
125
Hours
Every
1000
Hours
Every
8000 *
Hours
Every
Year
Change Air Filter ................................................................
•
Change Oil Separator ........................................................
•
Check Reservoir Oil Level .................................................
•
Check for Proper Load/Unload...........................................
•
Check Discharge Pressure/Temp.......................................
•
Check Dirt Accumulation on Cooler....................................
•
Change Oil Filter Element...................................................
•
•
Change Compressor Lubricant (AEON 9000SP) * ............
•
•
Check Relief Valve.............................................................
•
* See Oil Change Interval Chart, Figure 5-7, page 46, for specific lubricant life.
Содержание AUTO SENTRY EAU99G
Страница 10: ...13 10 614 Page 3 Figure 1 2 STARTER BOX Figure 1 3 PACKAGE CONTROLLER STARTERS 201EAU797 Ref Drawing...
Страница 11: ...13 10 614 Page 4 Figure 1 4 PACKAGE DRIVE MOTOR AIR FILTER 201EAU797 Ref Drawing...
Страница 14: ...13 10 614 Page 7 DECALS 206EAQ077 212EAQ077 218EAQ077 211EAQ077 207EAQ077...
Страница 15: ...13 10 614 Page 8 DECALS 216EAQ077 217EAQ077 222EAQ077 221EAQ077 208EAQ077...
Страница 37: ...13 10 614 Page 30 Figure 4 7 CONTROL SCHEMATIC COMPRESSOR AT FULL LOAD 206EAU797 A Ref Drawing...
Страница 41: ...13 10 614 Page 34 202EAU546 D Ref Drawing Page 2 of 2...
Страница 43: ...13 10 614 Page 36 205EAU546 D Ref Drawing Page 2 of 2...
Страница 47: ...13 10 614 Page 40 Figure 5 3 FLOW DIAGRAM 210EAU797 A Ref Drawing...