13-10-614 Page 14
INLET LINE
- Where an inlet line is used between the air filter and the compressor, it must be thoroughly
cleaned on the inside to prevent dirt or scale from entering the compressor. If welded construction is
used, the line must be shot blasted and cleaned to remove welding scale. In either case, the inlet line
must be coated internally by galvanizing or painting with a moisture and oil-proof sealing lacquer. Up to
ten (10) feet (3 meters) in length, the inlet line should be the full size of the inlet opening on the
compressor. If an extra-long line is necessary, the pipe size should be increased according to Inlet Line
Length Chart Figure 2-4, page 13.
Accessibility for inlet air filter servicing must be considered when relocating the filters from the unit to a
remote location.
DISCHARGE SERVICE LINE
- The discharge service line connection on both water-cooled and air-
cooled units is located at the right hand corner of the unit, viewed from the opposite end from control
panel side. When manifolding two or more rotary screw units on the same line, each unit is isolated by
the check valve in the unit discharge line. If a rotary screw unit is manifolded to another compressor, be
sure the other compressor has a check valve in the line between the machine and the manifold. If a
rotary screw and a reciprocating compressor are manifolded together, an air receiver must be located
between the two units.
DANGER
Discharge air used for breathing will cause severe injury or death.
Consult filtration specialists for additional filtration and treatment equipment to
meet health and safety standards.
HEAT EXCHANGER (DOMESTIC)
Water Temperature to Heat
Exchanger
(gpm)
HP
Model
60
°
F
70
°
F
80
°
F
90
°
F
Maximum
Water Flow
(gpm) *
Approximate Water
Pressure Drop @ 90
°
F
Water Temperature
(psi)
200 HP
EAU99G & M
18.8
23.5
31.3
47.0
110
1.1
250 HP
EAU99G & M
23.9
29.9
39.8
59.8
110
1.6
300 HP
EAU99G & M
29.1
36.3
48.5
72.7
110
2.1
* Flows exceeding "Maximum Water Flow" will cause severe erosion and will void unit warranty.
Содержание AUTO SENTRY EAU99G
Страница 10: ...13 10 614 Page 3 Figure 1 2 STARTER BOX Figure 1 3 PACKAGE CONTROLLER STARTERS 201EAU797 Ref Drawing...
Страница 11: ...13 10 614 Page 4 Figure 1 4 PACKAGE DRIVE MOTOR AIR FILTER 201EAU797 Ref Drawing...
Страница 14: ...13 10 614 Page 7 DECALS 206EAQ077 212EAQ077 218EAQ077 211EAQ077 207EAQ077...
Страница 15: ...13 10 614 Page 8 DECALS 216EAQ077 217EAQ077 222EAQ077 221EAQ077 208EAQ077...
Страница 37: ...13 10 614 Page 30 Figure 4 7 CONTROL SCHEMATIC COMPRESSOR AT FULL LOAD 206EAU797 A Ref Drawing...
Страница 41: ...13 10 614 Page 34 202EAU546 D Ref Drawing Page 2 of 2...
Страница 43: ...13 10 614 Page 36 205EAU546 D Ref Drawing Page 2 of 2...
Страница 47: ...13 10 614 Page 40 Figure 5 3 FLOW DIAGRAM 210EAU797 A Ref Drawing...