13-10-614 Page 46
Figure 5-6 – OIL LEVEL GAUGE
OIL LEVEL GAUGE
(Figure 1-2, page 3 and Figure 5-6) indicates the amount of oil in the oil reservoir.
Read oil level only when unit is on. In operation the oil level will fluctuate as the compressor loads and
unloads. Add oil only when the oil is at the bottom of the red range on the gauge as read when the
compressor is on. Drain oil only when the oil level is above the center of the green range on the gauge
as read when the compressor is on.
OIL CHANGE INTERVAL
- Recommended oil change intervals are based on oil temperature. Figure 5-7,
shows how the change interval is affected by temperature.
Discharge
Temperature
AEON 4000
Change Interval
AEON 9000SP
Change Interval
Up to 180
°
F (82
°
C)
4000 hrs.
8000 hrs.
180
°
F to 190
°
F (82
°
C to 88
°
C)
3000 hrs.
6000 hrs.
190
°
F to 200
°
F (88
°
C to 93
°
C)
2000 hrs.
4000 hrs.
200
°
F+ (93
°
C)
1000 hrs.
2000 hrs.
Figure 5-7 – OIL CHANGE INTERVAL
Содержание AUTO SENTRY EAU99G
Страница 10: ...13 10 614 Page 3 Figure 1 2 STARTER BOX Figure 1 3 PACKAGE CONTROLLER STARTERS 201EAU797 Ref Drawing...
Страница 11: ...13 10 614 Page 4 Figure 1 4 PACKAGE DRIVE MOTOR AIR FILTER 201EAU797 Ref Drawing...
Страница 14: ...13 10 614 Page 7 DECALS 206EAQ077 212EAQ077 218EAQ077 211EAQ077 207EAQ077...
Страница 15: ...13 10 614 Page 8 DECALS 216EAQ077 217EAQ077 222EAQ077 221EAQ077 208EAQ077...
Страница 37: ...13 10 614 Page 30 Figure 4 7 CONTROL SCHEMATIC COMPRESSOR AT FULL LOAD 206EAU797 A Ref Drawing...
Страница 41: ...13 10 614 Page 34 202EAU546 D Ref Drawing Page 2 of 2...
Страница 43: ...13 10 614 Page 36 205EAU546 D Ref Drawing Page 2 of 2...
Страница 47: ...13 10 614 Page 40 Figure 5 3 FLOW DIAGRAM 210EAU797 A Ref Drawing...