13-10-614 Page 37
SECTION 5
LUBRICATION
OIL COOLER, OIL FILTER & SEPARATOR
COMPRESSOR OIL SYSTEM
(
Figure 5-3
, page 40) cools the compressor, lubricates moving parts and
seals internal clearances in the compression chamber.
The oil inlet line is connected at the bottom of the oil reservoir. Air pressure in the oil reservoir forces oil
through the oil cooler, thermostatic mixing valve, oil filter and into the compressor main oil gallery.
The oil passes through internal passages for lubrication, cooling and sealing. The air-oil mixture is then
discharged to the oil reservoir where a large part of the entrained oil drops out of the air stream; the air
then passes through the final oil separator where most of the remaining oil is removed. The separated oil
is returned to the compressor and the air passes to the final discharge line.
RECOMMENDED LUBRICANT
- Gardner Denver compressors are factory filled with AEON lubricants.
These lubricants are formulated to the highest quality standards and are factory authorized, tested and
approved for use in rotary screw compressors. AEON lubricants are available through your authorized
Gardner Denver compressor distributor.
OIL SPECIFICATIONS: EAU
(Domestic and International) - The factory fill compressor lubricant is
Gardner Denver AEON 9000SP lubricating coolant which can be used for year-round operation. AEON
9000SP is a synthetic, extended life lubricant which can extend lubricant change intervals up to 4 times
that of a petroleum based lubricant.
A lubricant analysis program for a periodic check of lubricant quality and remaining life can maximize the
change interval. An oil sampling valve has been installed in a blank line piped to an opening in the filter
stat. Use this valve to get lubricant to send in for analysis.
CAUTION
Use of improper lubricants will cause damage to equipment. Do not mix
different types of lubricants or use inferior lubricants.
CAUTION
Improper equipment maintenance with use of synthetic lubricants will damage
equipment. For oil filter and oil separator change intervals remain the same as
for AEON 4000, see Maintenance Schedule, page 63.
Содержание AUTO SENTRY EAU99G
Страница 10: ...13 10 614 Page 3 Figure 1 2 STARTER BOX Figure 1 3 PACKAGE CONTROLLER STARTERS 201EAU797 Ref Drawing...
Страница 11: ...13 10 614 Page 4 Figure 1 4 PACKAGE DRIVE MOTOR AIR FILTER 201EAU797 Ref Drawing...
Страница 14: ...13 10 614 Page 7 DECALS 206EAQ077 212EAQ077 218EAQ077 211EAQ077 207EAQ077...
Страница 15: ...13 10 614 Page 8 DECALS 216EAQ077 217EAQ077 222EAQ077 221EAQ077 208EAQ077...
Страница 37: ...13 10 614 Page 30 Figure 4 7 CONTROL SCHEMATIC COMPRESSOR AT FULL LOAD 206EAU797 A Ref Drawing...
Страница 41: ...13 10 614 Page 34 202EAU546 D Ref Drawing Page 2 of 2...
Страница 43: ...13 10 614 Page 36 205EAU546 D Ref Drawing Page 2 of 2...
Страница 47: ...13 10 614 Page 40 Figure 5 3 FLOW DIAGRAM 210EAU797 A Ref Drawing...