37- 1- 613 Page 22
EMERGENCIES – In event of system failures, shutdown the blower immediately. Inspect the blower for
foreign material backflow. If materials are found inside the blower housing, a thorough cleaning is
necessary before restarting.
Do not operate a blower which is noisy, vibrating, or heating excessively.
Models
Minimum Speed (RPM) - Dry Pressure
Up To
15 PSIG
18 PSIG
20 PSIG
5CDL5
5CDL9
5CDL13
1900
1780
1625
2700
2300
2300
4200
2900
2900
Models
Minimum Speed (RPM)
Dry Vacuum
Wet Vacuum
Up To
17” Hg.
Up To
22” Hg.
24” Hg.
5CDL5
5CDL9
5CDL13
2950
2900
2850
1500
1500
1500
2000
1500
1500
FIGURE 3- 6 – MINIMUM SPEED, MAXIMUM PRESSURE OR VACUUM