English - 53
6. MENU FUNCTIONS
Calibrate guide, R40Li
The
Calibrate guide
function allows you to test if the
robotic lawnmower can follow the guide wire out from
the charging station.
To test the guide wire:
1.
Place the robotic lawnmower in the charging
station.
2.
Select
Calibrate guide
and press
OK
. The
robotic lawnmower will now leave the charging
station, run a calibration process in front of the
charging station and then follow the guide wire to
the connection point with the boundary wire and
then start mowing.
3.
Check that the robotic lawnmower can follow the
guide wire all the way to the connection point
with the boundary wire.
The test has failed if the robotic lawnmower
cannot follow the guide wire all the way to the
connection point with the boundary wire. It is likely
that the installation has not been carried out
‚Äã‚Äãin accordance with the instructions in
3. Installation
. Common errors are for instance
that there is not enough open space to the left of
the guide wire as seen facing the charging station
or that the guide wire is not laid at an angle on a
steep slope. See
3.6 Installation of the guide wire
.
Rectify the installation and run a new test
with
Calibrate guide, R40Li
.
Reset user settings
This function allows you to reset the robotic
lawnmower to the default settings it had when it left the
factory.
1.
Select
Reset user settings
in the menu and press
OK
. Enter the correct PIN code and press
OK
.