3. INSTALLATION
It is possible to let the low voltage cable cross the
working area. The low voltage cable must be stapled
down or buried, and the cutting height should be such
that the blades on the blade disc can never come in
contact with the low voltage cable.
Make sure the low voltage cable is laid along the
ground and secured with pegs. The cable must lie
close to the ground so as not to be cut before the
grass roots have grown over it.The low voltage cable
must never be stored in a coil or under the charging
station's base plate as this can interfere with the
signals from the charging station.
The low voltage cable must never be stored in a coil
or under the charging station’s base plate as this can
interfere with the signals from the charging station.
The transformer must be placed where it is well
ventilated and is not exposed to direct sunlight. The
transformer must be placed under a roof.
It is recommended to use an earth fault-breaker when
connecting the transformer to the wall socket.
If the transformer cannot be plugged directly into a
wall outlet, do not under any circumstances mount
the transformer at a height where there is a risk it can
be submerged in water (at least 30 cm from the
ground). It is not permitted to place the transformer
on the ground.
IMPORTANT INFORMATION
The low voltage cable must not under any
circumstances be shortened or extended.
IMPORTANT INFORMATION
Place the low voltage cable so that the blades
on the blade disc can never come in contact
with it.
IMPORTANT INFORMATION
Use the plug to disconnect the charging
station, for instance before cleaning or
repairing the loop wire.