This radiation is harmful to eyes and skin.

Never operate the UV unit when the
housing has been removed.

Electrical safety :

v

v

Inspect the equipment before use to 
ensure that the pump and the UVC unit,
especially the power cable and plug, are
undamaged.

Do not use a damaged UVC unit or pump.

Do not use the light if the connection lead,
glass tube or the housing of the UVC unit
appear to be defective.

If the pump or UVC unit is damaged, please
have them checked by our GARDENA Service
Centre or an authorised electrician.

The UVC-unit and the pump must be operat-
ed via a residual-current device (FI-switch)
with a nominal fault current 

30 mA (DIN

VDE 0100-702 and 0100-738).

v

Please ask your electrician for his advice.

Mains power cables should not have a smaller
cross-section than a rubber sheathed cable of
the designation H05 RNF.
Extension cables must meet the requirements
of DIN VDE 0620.

The information on the model plate of the
UVC unit must match the power supply.

The connection cable of the UVC-unit and the
pump cannot be replaced.
If the cable is damaged the UV unit must be
scrapped.

Do not use extension leads, connection leads
or adapters without a protective contact.

The fountain pump must not be operated
when there are people in the water.
Swimming pools and garden ponds should 
be designed according to international and
national design regulations.

v

Please ask your electrician for his advice.

Never carry the UVC-unit and the pump by the
cable. Do not pull on the cable to unplug the
plug from the socket.

Please protect the cable from heat, oil and
sharp edges. Make sure that connection
points remain dry.

Always unplug the equipment when dis-
mantling the set, when it is not in use and
before maintenance.

v

Always disconnect the UVC unit and the
pump from the mains before undertaking
any work on them.

For Austria 

In Austria power cables should correspond to
ÖVE-EM 42, T 2 (2000) /1979 § 22 according
to § 2022.1. According to this standard units
used in swimming pools and ponds should 
only be operated via an isolating transformer.

v

Please contact your electrician.

For Switzerland 

In Switzerland mobile appliances which are
used outdoors, must be connected via a 
residual-current device.

Notes :

Never operate the UVC unit without water
throughput.

Never let the pump run dry; running dry
generates heat and will damage the pump.

Sand and other abrasive substances in the 
liquid cause increased wear and reduce the
output of the pump.

The temperature of the liquid used must not
be below 4 °C or above 35 °C.

Safety switch :

If the UVC light overheats, it is switched off 
by the built-in thermal protection switch. The
UVC light switches itself on again automati-
cally when it has cooled down sufficiently.

Due to the integrated safety switch the lamp
only comes on when the UVC unit is properly
installed.

Positioning the filter :

v

Stand or bury the filter housing in a stable
position at least 2 m away next to the 
garden pond.

The filter must be positioned higher than the
surface of the pond.

Bacterial Activity :

Extensive bacterial activity arises 
from + 10 °C onwards.

The filter system is a biological system and
therefore, when newly installed, needs a few
weeks until it is fully effective.

If possible, the filter should be in permanent
operation from spring to autumn and should
not dry out.

Содержание F 5000 S

Страница 1: ...ilter Set F Mode d emploi Kit filtre de bassin UVC NL Instructies voor gebruik UVC vijverfilterset S Bruksanvisning UVC dammfiltersats I Istruzioni per l uso Set filtro per laghetti UVC E Manual de in...

Страница 2: ...safe place 1 Range of Uses for Your GARDENA UVC Pond Filter Set 11 2 Safety Instructions 11 3 Function 13 4 Assembly 13 5 Initial Operation 14 6 Maintenance 15 7 Trouble Shooting 16 8 Putting out of...

Страница 3: ...ble from heat oil and sharp edges Make sure that connection points remain dry Always unplug the equipment when dis mantling the set when it is not in use and before maintenance v Always disconnect the...

Страница 4: ...and remove carefully 2 bayonet fitting see 7 Trouble Shooting Changing the bulb 2 Push the two bolts 3 into the guides on the UVC unit 2 and place on the filter cover 4 3 From underneath screw one wa...

Страница 5: ...a stable position at least 2 m away next to the garden pond The outlet may not be more than 1m above the surface of the pond Set up the UVC pond filter horizontally so that the filter cannot overflow...

Страница 6: ...order see 4 Assembly Assembling the UVC filter 6 Restart the filter see 5 Using for the First Time Starting the UVC pond filter 1 Take pump out of the water 2 Unscrew the connecting hose 3 Unlock snap...

Страница 7: ...ARNING Short circuit A v v The ring W must be screwed on firmly again to guarantee that the glass tube U is sealed When installing make sure that the O ring Y fits properly on the glass tube U and tha...

Страница 8: ...t on Bulb defective v Change bulb Electrical connections defective v Check electrical connections A In the event of other faults please contact GARDENA Service Repairs should only be carried out by GA...

Страница 9: ...vice Warranty GARDENA provides a 2 year warranty on this product and a 3 year warranty on the pump from date of purchase This guarantee covers all serious defects of the unit that can be proved to be...

Страница 10: ...di rendimento Curva caracter stica de la bomba Caracter sticas de performance Ydelses karakteristika F 5000 S Art 7932 Pumpen Kennlinie Performance characteristics Courbes de performance Prestatiegra...

Страница 11: ...n om skadan beror p att produkten har reparerats felaktigt eller om vid repa ration eller utbyte andra n Original GARDENA reservdelar har anv nts Samma sak g ller f r kompletteringsdelar och tillbeh r...

Страница 12: ...onforme aux r gles de s curit et autres r gles qui lui sont applicables dans le cadre de l Union europ enne Toute modification port e sur ce produit sans l accord express de GARDENA supprime la validi...

Страница 13: ...Reykjavik ooj ojk is Ireland Michael McLoughlin Sons Hardware Limited Long Mile Road Dublin 12 Italy GARDENA Italia S p A Via Donizetti 22 20020 Lainate Mi Phone 39 02 93 94 79 1 info gardenaitalia i...

Отзывы: