background image

Info-LED:

In the case of a fault, the Info LED displays the corresponding 

disturbance states through various flashing frequencies, each with 

a 2 second break.

Info-LED blinks 

1 time

Problem with the initial  operation  

(In case of fault, display appears 30 seconds 

after the Electronic Pressure Pump is 

 switched  on)

Info-LED blinks 

2 times

Problem with the initial operation  

(In case of fault, display appears 6 minutes 

after the Electronic Pressure Pump is 

 switched  on)

Info-LED blinks 

3 times

Problem during the current  operation  

(In case of fault, display appears 30 seconds 

after the Electronic Pressure Pump is 

 switched  on)

Info-LED blinks 

4 times

Problem during the current  operation  

(In case of fault, display appears 60 minutes 

after the Electronic Pressure Pump is 

 switched  on)

The Fault Indicator is deleted by switching off the pump or pulling 

the mains plug.

Problem 

Possible Cause

Remedy

Info-LED blinks once.

During the initial operation,  

the pump did not suck water  

for 30 seconds.

The pump sucks nothing up

Pump was not sufficiently filled 

with liquid to be pumped.

v  

Fill and secure the pump  

so that water does not drain  

out on the pressure side 

during the suctioning 

 process (see 4. Operation).

Air cannot escape on the pres-

sure side, because the  pressure 

side outlets are closed.

v

  Open the pressure side 

 outlets (see 4. Operation).

Pump motor does not start 

Thermal circuit breaker  

activated and the pump  

housing is heated.

1.  Change the switch to 

O.

2.  Open possible existing  

shut-off device in the pres-

sure line (release pressure).

3.  Ensure sufficient ventilation 

and allow the pump to cool 

for approx. 20 min. 

4.  Restart the pump  

(see 4. Operation).

Pump is blocked.

v  

Manually remove the 

 blockage  (see  “Free the 

impeller”).

v  

Allow the pump to cool down 

for 20 minutes.

22

EN

Содержание Classic 3500/4E

Страница 1: ...for HU Használati utasítás Háztartási automata szivattyú CS Návod k obsluze Domácí vodní automat SK Návod na obsluhu Domáci vodný automat EL Οδηγίες χρήσης Συσκευή παραγωγής νερού οικιακής χρήσης RU Инструкция по эксплуатации Автоматический напорный насос SL Navodilo za uporabo Hišna vodni avtomat HR Upute za uporabu Kućni automat za vodu SR Uputstvo za rad BS Hidropak UK Інструкція з експлуатації...

Страница 2: ... the pump pressure have to be added together Example pressure at the tap 2 0 bar maximum pressure of the Electronic Pressure Pump 3500 4E 3 5 bar total pressure 5 5 bar Liquids pumped The GARDENA Electronic Pressure Pump can be used for pumping rainwater tap water and chlorinated water IMPORTANT The GARDENA Electronic Pressure Pump is not suitable for continuous operation e g industrial applicatio...

Страница 3: ...e powered through an isolating trans former v Please ask your electrician for his advice In Switzerland In Switzerland portable devices that are used outdoors must be connected through a residu al current device General Information DANGER Scalding from hot water The water can get very hot during operation particularly if only small quantities are drawn v Before carrying out any work on the pump al...

Страница 4: ...me is automatically reset to normal operation of the Electronic Pressure Pump and allows a trouble free use of the washing machine for 60 minutes Info LED The pump is equipped with a faults diagnostics system where various disturbance states can be determined by the Info LED see 7 Troubleshooting 3 Installation Positioning of Electronic Pressure Pump The installation position must be firm and dry ...

Страница 5: ...on the connection fit tings with the upmost care Use sealing tape only for sealing metallic connection fittings Suction inlet Art 1723 Art 1724 4 3 2 Do not use any water hose snap connection system components on the intake side A vacuum tight suction hose must be used e g GARDENA Suction Hose Art no 1411 1418 GARDENA Bore Hole Suction Hose Art no 1729 GARDENA Suction Hose sold by the metre and Ar...

Страница 6: ... in the liquid to be pumped via the filler connection 0 up to the overflow approx 2 to 3 l until the water level no longer drops under the suction side inlet or the water flows out at the horizontal connector With fixed installations unscrew the black lid r and fill with liquid until it flows towards the horizontal connector 3 Empty any water remaining in the delivery hose so that the air can esca...

Страница 7: ... the Electronic Pressure Pump must be emptied and stored where it will not become frozen Store out of the reach of children 1 Change the switch q to O 2 Unplug the mains connection for the pump 3 Open the delivery side consumer 4 Remove the connected hoses on the pressure and suction sides 5 Unscrew drain bolt 1 6 Tilt the pump to the suction and pressure side until water is no longer discharged f...

Страница 8: ... Art no 1758 2 Disconnect mains plug 3 If necessary close all valves on the intake side 4 Open all pressure side outlets so that the pressure side is depressurised Afterwards close the tapping points again in order to prevent the con nected lines running empty via the Electronic Pressure Pump 5 Screw out the cover r of the check valve using a suitable tool 6 Remove the valve body t and wash it und...

Страница 9: ...Fault Indicator is deleted by switching off the pump or pulling the mains plug Problem Possible Cause Remedy Info LED blinks once During the initial operation the pump did not suck water for 30 seconds The pump sucks nothing up Pump was not sufficiently filled with liquid to be pumped v Fill and secure the pump so that water does not drain out on the pressure side during the suctioning process see...

Страница 10: ...rcuit breaker activated motor overheated v Allow the pump to cool down for 20 minutes Info LED blinks 3 times During the current operation the pump has extracted no water for 30 seconds Water supply disrupted on the suction side Problem on pump side v Immerse suction hose end under water v eliminate leak on the suction side v clean check valve on the suction line and check the mounting direction v...

Страница 11: ... GARDENA Service Switch is not turned to I v Restart the pump see 4 Operation Mains plug not plugged in v Insert mains plug into a mains socket 230 V AC Power failure v Check fuse and cables Free the impeller z An impeller blocked by dirt can be freed again v Turn motor shaft z using a screw driver This will free the blocked impeller For Art no 1758 only Cleaning the flow sensor i u p s a o If the...

Страница 12: ...e For vacuum resistant connection of the pump to boreholes or pipe networks Length 0 5 m With 33 3 mm G1 female thread at both ends Art no 1729 GARDENA Connection Set Connection Set for 1 2 Pressure Hoses Art no 1750 GARDENA Connection Set Connection Set for 3 4 Pressure Hoses Art no 1752 9 Technical Data Type Classic 3500 4E Art no 1757 Comfort 4000 5E Art no 1758 Voltage Frequency 230 V AC 50 Hz...

Страница 13: ...following provisions The product was used for its intended purpose as per the recommendations in the operating instructions Neither the purchaser nor a third party has attempted to repair the product This manufacturer s warranty does not affect warranty entitlements against the dealer retailer If problems arise with this product please contact our Service department or send the defective product a...

Страница 14: ...i ikke påtager os noget ansvar for skader på vores produkter hvis de pågældende produkter ikke er blevet repareret korrekt af en GARDENA godkendt servicepartner eller hvor der ikke er brugt originale GARDENA reservedele eller godkendte reservedele fra GARDENA FI Tuotevastuu Saksan tuotevastuulain mukaisesti emme ole vastuussa laitteiden vaurioista jos korjauksia ei ole tehnyt GARDENAn hyväksymä hu...

Страница 15: ...oda ovime izričito izjavljujemo kako ne prihvaćamo nikakvu odgovornost za oštećenja na našim proizvodima nastala uslijed neispravnog popravka od strane servisnog partnera kojeg odobrava GARDENA ili uslijed nekorištenja originalnih GARDENA dijelova ili dijelova koje odobrava GARDENA RO Răspunderea pentru produs În conformitate cu Legea germană privind răspunderea pentru produs declarăm în mod expre...

Страница 16: ...j wyroby opuszczające fabrykę są zgodne ze zharmonizowanymi normami UE oraz z obowiązującymi w UE przepisami bezpieczeństwa i normami dotyczącymi danego produktu Modyfikacja wyrobów bez naszej zgody powoduje unieważnienie niniejszego certyfikatu HU EK megfelelőségi nyilatkozat Alulírott Husqvarna AB 561 82 Huskvarna Svédország ezzel tanúsítja hogy az alábbiakban leírt egységek a gyár elhagyásakor ...

Страница 17: ...ion du marquage CE Installatiejaar van de CE aanduiding Märkningsår CE Mærkningsår CE merkin kiinnitysvuosi Anno di applicazione della certificazione CE Colocación del distintivo CE Ano de marcação pela CE Rok nadania oznakowania CE CE jelzés elhelyezésének éve Rok umístění značky CE Rok udelenia značky CE Έτος σήματος CE Leto namestitve CE oznake Godina dobivanja CE oznake Anul de marcare CE Годи...

Страница 18: ...akteristiky čerpadla Χαρακτηριστικό διάγραμμα Характеристика насоса Karakteristika črpalka Obilježja pumpe Karakteristika pumpe Крива характеристики насоса Caracteristică pompă Pompa karakter eğrisi Помпена характеристика Fuqia e pompës Pumba karakteristik Siurblio charakteristinė kreivė Sūkņa raksturlīkne Classic 3500 4E 5 4 3 2 1 0 bar m 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 l h 50 ...

Страница 19: ...chia 15 23868 VALMADRERA LC Phone 39 0341 203 111 assistenza italia it husqvarna com Japan KAKUICHI Co Ltd Sumitomo Realty Development Kojimachi BLDG 8F 5 1 Nibanncyo Chiyoda ku Tokyo 102 0084 Phone 81 33 264 4721 m_ishihara kaku ichi co jp Kazakhstan LAMED Ltd 155 1 Tazhibayevoi Str 050060 Almaty IP Schmidt Abayavenue 3B 110 005 Kostanay Korea Kyung Jin Trading CO LTD 107 4 SunDuk Bld YangJae don...

Отзывы: