background image

2. Function

The Electronic Pressure Pump is equipped with an electronic 

 control which automatically turns on the pump when the cut-in 

pressure has fallen and automatically switches off when no  

more water is extracted.

Low quantity programme 

(Leakage Warning):

The low quantity programme allows for trouble-free use of, for 

example, modern washing machines or drip irrigation systems, 

even with low water flow. Operating interval: Up to 60 minutes 

(leakage warning may be triggered after 60 minutes).

Note: The cyclical activation and deactivation of the 

 Electronic Pressure Pump in small amount mode is due  

to the system design and does not have any impact on  

pump life.

For irrigation: If the low quantity programme is to be used for 

more than 60 minutes, irrigation must be disrupted for at least 

5 minutes before the end of the 60 minute period. The small 

amount programme can then be used for a further 60 minutes.
Use of washing machines: Upon completion of the minimum 

amount water supply cycle in washing machines, the 60-minute 

operating interval of the low quantity programme is automatically 

reset to normal operation of the Electronic Pressure Pump and 

allows a trouble-free use of the washing machine for > 60 minutes.

Info-LED:

The pump is equipped with a faults diagnostics system where 

 various disturbance states can be determined by the Info LED  

(see 7. Troubleshooting).

 

3. Installation

Positioning of Electronic  

Pressure Pump:

The installation position must be firm and dry, and permit a secure 

mounting for the Electronic Pressure Pump.

 Install the Electronic Pressure Pump at a safe distance  

(min. 2 m) from the  pumping medium.

The pump must be installed in a location with an air humidity of  

< 80 % and sufficient ventilation in the area of the ventilation slots. 

It must be at a distance of at least 5 cm from the walls. No dirt 

contamination (e. g. sand or earth) may be sucked in through the 

ventilation slots.

some conditions interfere with active or passive 

medical implants. To decrease the risk of condi-

tions that can possibly injure or kill, we recom-

mend persons with medical implants to speak 

with their physician and the medical implant 

manufacturer before you operate the product.

DANGER! Small parts can be easily swallowed. 

There is also a risk that the polybag can 

 suffocate toddlers. Keep toddlers away when 

you assemble the product.

17

EN

Содержание Classic 3500/4E

Страница 1: ...for HU Használati utasítás Háztartási automata szivattyú CS Návod k obsluze Domácí vodní automat SK Návod na obsluhu Domáci vodný automat EL Οδηγίες χρήσης Συσκευή παραγωγής νερού οικιακής χρήσης RU Инструкция по эксплуатации Автоматический напорный насос SL Navodilo za uporabo Hišna vodni avtomat HR Upute za uporabu Kućni automat za vodu SR Uputstvo za rad BS Hidropak UK Інструкція з експлуатації...

Страница 2: ... the pump pressure have to be added together Example pressure at the tap 2 0 bar maximum pressure of the Electronic Pressure Pump 3500 4E 3 5 bar total pressure 5 5 bar Liquids pumped The GARDENA Electronic Pressure Pump can be used for pumping rainwater tap water and chlorinated water IMPORTANT The GARDENA Electronic Pressure Pump is not suitable for continuous operation e g industrial applicatio...

Страница 3: ...e powered through an isolating trans former v Please ask your electrician for his advice In Switzerland In Switzerland portable devices that are used outdoors must be connected through a residu al current device General Information DANGER Scalding from hot water The water can get very hot during operation particularly if only small quantities are drawn v Before carrying out any work on the pump al...

Страница 4: ...me is automatically reset to normal operation of the Electronic Pressure Pump and allows a trouble free use of the washing machine for 60 minutes Info LED The pump is equipped with a faults diagnostics system where various disturbance states can be determined by the Info LED see 7 Troubleshooting 3 Installation Positioning of Electronic Pressure Pump The installation position must be firm and dry ...

Страница 5: ...on the connection fit tings with the upmost care Use sealing tape only for sealing metallic connection fittings Suction inlet Art 1723 Art 1724 4 3 2 Do not use any water hose snap connection system components on the intake side A vacuum tight suction hose must be used e g GARDENA Suction Hose Art no 1411 1418 GARDENA Bore Hole Suction Hose Art no 1729 GARDENA Suction Hose sold by the metre and Ar...

Страница 6: ... in the liquid to be pumped via the filler connection 0 up to the overflow approx 2 to 3 l until the water level no longer drops under the suction side inlet or the water flows out at the horizontal connector With fixed installations unscrew the black lid r and fill with liquid until it flows towards the horizontal connector 3 Empty any water remaining in the delivery hose so that the air can esca...

Страница 7: ... the Electronic Pressure Pump must be emptied and stored where it will not become frozen Store out of the reach of children 1 Change the switch q to O 2 Unplug the mains connection for the pump 3 Open the delivery side consumer 4 Remove the connected hoses on the pressure and suction sides 5 Unscrew drain bolt 1 6 Tilt the pump to the suction and pressure side until water is no longer discharged f...

Страница 8: ... Art no 1758 2 Disconnect mains plug 3 If necessary close all valves on the intake side 4 Open all pressure side outlets so that the pressure side is depressurised Afterwards close the tapping points again in order to prevent the con nected lines running empty via the Electronic Pressure Pump 5 Screw out the cover r of the check valve using a suitable tool 6 Remove the valve body t and wash it und...

Страница 9: ...Fault Indicator is deleted by switching off the pump or pulling the mains plug Problem Possible Cause Remedy Info LED blinks once During the initial operation the pump did not suck water for 30 seconds The pump sucks nothing up Pump was not sufficiently filled with liquid to be pumped v Fill and secure the pump so that water does not drain out on the pressure side during the suctioning process see...

Страница 10: ...rcuit breaker activated motor overheated v Allow the pump to cool down for 20 minutes Info LED blinks 3 times During the current operation the pump has extracted no water for 30 seconds Water supply disrupted on the suction side Problem on pump side v Immerse suction hose end under water v eliminate leak on the suction side v clean check valve on the suction line and check the mounting direction v...

Страница 11: ... GARDENA Service Switch is not turned to I v Restart the pump see 4 Operation Mains plug not plugged in v Insert mains plug into a mains socket 230 V AC Power failure v Check fuse and cables Free the impeller z An impeller blocked by dirt can be freed again v Turn motor shaft z using a screw driver This will free the blocked impeller For Art no 1758 only Cleaning the flow sensor i u p s a o If the...

Страница 12: ...e For vacuum resistant connection of the pump to boreholes or pipe networks Length 0 5 m With 33 3 mm G1 female thread at both ends Art no 1729 GARDENA Connection Set Connection Set for 1 2 Pressure Hoses Art no 1750 GARDENA Connection Set Connection Set for 3 4 Pressure Hoses Art no 1752 9 Technical Data Type Classic 3500 4E Art no 1757 Comfort 4000 5E Art no 1758 Voltage Frequency 230 V AC 50 Hz...

Страница 13: ...following provisions The product was used for its intended purpose as per the recommendations in the operating instructions Neither the purchaser nor a third party has attempted to repair the product This manufacturer s warranty does not affect warranty entitlements against the dealer retailer If problems arise with this product please contact our Service department or send the defective product a...

Страница 14: ...i ikke påtager os noget ansvar for skader på vores produkter hvis de pågældende produkter ikke er blevet repareret korrekt af en GARDENA godkendt servicepartner eller hvor der ikke er brugt originale GARDENA reservedele eller godkendte reservedele fra GARDENA FI Tuotevastuu Saksan tuotevastuulain mukaisesti emme ole vastuussa laitteiden vaurioista jos korjauksia ei ole tehnyt GARDENAn hyväksymä hu...

Страница 15: ...oda ovime izričito izjavljujemo kako ne prihvaćamo nikakvu odgovornost za oštećenja na našim proizvodima nastala uslijed neispravnog popravka od strane servisnog partnera kojeg odobrava GARDENA ili uslijed nekorištenja originalnih GARDENA dijelova ili dijelova koje odobrava GARDENA RO Răspunderea pentru produs În conformitate cu Legea germană privind răspunderea pentru produs declarăm în mod expre...

Страница 16: ...j wyroby opuszczające fabrykę są zgodne ze zharmonizowanymi normami UE oraz z obowiązującymi w UE przepisami bezpieczeństwa i normami dotyczącymi danego produktu Modyfikacja wyrobów bez naszej zgody powoduje unieważnienie niniejszego certyfikatu HU EK megfelelőségi nyilatkozat Alulírott Husqvarna AB 561 82 Huskvarna Svédország ezzel tanúsítja hogy az alábbiakban leírt egységek a gyár elhagyásakor ...

Страница 17: ...ion du marquage CE Installatiejaar van de CE aanduiding Märkningsår CE Mærkningsår CE merkin kiinnitysvuosi Anno di applicazione della certificazione CE Colocación del distintivo CE Ano de marcação pela CE Rok nadania oznakowania CE CE jelzés elhelyezésének éve Rok umístění značky CE Rok udelenia značky CE Έτος σήματος CE Leto namestitve CE oznake Godina dobivanja CE oznake Anul de marcare CE Годи...

Страница 18: ...akteristiky čerpadla Χαρακτηριστικό διάγραμμα Характеристика насоса Karakteristika črpalka Obilježja pumpe Karakteristika pumpe Крива характеристики насоса Caracteristică pompă Pompa karakter eğrisi Помпена характеристика Fuqia e pompës Pumba karakteristik Siurblio charakteristinė kreivė Sūkņa raksturlīkne Classic 3500 4E 5 4 3 2 1 0 bar m 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 l h 50 ...

Страница 19: ...chia 15 23868 VALMADRERA LC Phone 39 0341 203 111 assistenza italia it husqvarna com Japan KAKUICHI Co Ltd Sumitomo Realty Development Kojimachi BLDG 8F 5 1 Nibanncyo Chiyoda ku Tokyo 102 0084 Phone 81 33 264 4721 m_ishihara kaku ichi co jp Kazakhstan LAMED Ltd 155 1 Tazhibayevoi Str 050060 Almaty IP Schmidt Abayavenue 3B 110 005 Kostanay Korea Kyung Jin Trading CO LTD 107 4 SunDuk Bld YangJae don...

Отзывы: