7. Changing the Battery / Testing the Battery 

A

To ensure the Water Timer runs safely, only a 9 V alkali-
manganese battery (alkaline) type IEC 6LR61 must be used.

If the battery voltage falls below a 

certain level

the 

Batt

. indicator appears. 

It is possible to initiate watering manually
even if the battery capacity is too low
(valve no longer opens), but programmed
watering times, however, are not initiated. 

Even if the 

battery capacity is too low

to run a program, if the valve is

open it will be closed.

The battery voltage is tested 

between the opening and the closing

pulse.

In this way you can test the capability of the battery 

at any time. 

To do this, press two times the 

On / Off-man.

key. If the valve closes and

the 

Batt

. indicator does not appear then the battery is functioning. If the 

display disappears and only the 

Batt. 

indicator is visible, the battery has 

to be changed. 

A

Previously set data is lost when replacing the battery. 
Program the Water Timer subsequently again.

For notes on changing the battery see “Inserting the Battery”.

Hint ! 

Please return the flat battery to a GARDENA dealer or dispose of it

properly at your nearest recycling centre. Only dispose of battery 

when 

it is flat. 

8. Notes on Safety and Operation

.

The minimum water output to ensure that the Water Computer 
functions correctly is 20 - 30 l / h. 
For example, at least 10 x 2-litre Drip Heads are required to 
control the Micro-Drip-System. 

.

To prevent water penetrating the battery compartment the Water
Timer must only be mounted in a perpendicular position with 
the sleeve nut pointing upwards. 

.

Program the Water Timer with the tap turned off. In this way 
you can avoid getting wet when trying out the manual On / Off 
function. You can remove the control unit from the housing to 
program the Water Timer. 

.

The Water Timer must only be used outdoors. 
Warning ! The Water Timer must not be used indoors. 

·

Batt.

On

·

Off

·

28 .

.

88

3

·

Time 

·

Star

t

·

Cyc

le

38

Содержание C14

Страница 1: ...C 14 e D Betriebsanleitung Bew sserungsuhr electronic C 14 e GB Operating Instructions Water Timer Electronic C 14 e PL Instrukcja obs ugi Sterownik nawadniania electronic C 14 e RO Instruc iuni de ut...

Страница 2: ...z k Oldal E Manual de instrucciones 4 12 Garant a 69 P Instru es de utiliza o 13 21 Garantia 69 D Betriebsanleitung 22 32 Garantie 70 G Operating Instructions 33 41 Guarantee 70 p Instrukcja obs ugi 4...

Страница 3: ......

Страница 4: ...Keep these operating instructions in a safe place 2 Proper Use The GARDENA Water Timer Electronic C 14 e is suitable and determinated for private use in domestic and hobby gardens exclusively for outd...

Страница 5: ...ery compartment 9 GARDENA threaded tap 4 Connection plug for control unit connector 5 Release button for control unit 6 Connection for Soil Moisture Sensor Rain Sensor Option 7 Sleeve nut 0 Anti theft...

Страница 6: ...using the man key On Off man Used to change the individual data e g counting hours minutes To switch a connected watering system on and off manually LCD Display Note In the entry mode the correspondi...

Страница 7: ...ogram number you require appears on the display Note With the combination 00 Stand by no program is active 2 Confirm your selection by pressing the O K key You have now successfully programmed your Wa...

Страница 8: ...3 minutes 02 12 hours twice daily 3 minutes 03 12 hours twice daily 15 minutes 04 24 hours once a day 3 minutes 05 24 hours once a day 5 minutes 06 24 hours once a day 30 minutes 07 24 hours once a d...

Страница 9: ...s to be changed A Previously set data is lost when replacing the battery Program the Water Timer subsequently again For notes on changing the battery see Inserting the Battery Hint Please return the f...

Страница 10: ...not be loosened once it has been screwed in The bracket can be used for example to attach a chain 10 GARDENA Soil Moisture Sensor Fig E Together with the GARDENA Soil Moisture Sensor Art No 1188 water...

Страница 11: ...oil Moisture Sensor If dry check setting or Rain Sensor indi position of the Soil cate sufficient moisture Moisture Sensor or Rain Sensor Battery flat after Not an alkaline Use an alkaline working for...

Страница 12: ...r Electronic Type C 14 e Art No 1820 EU directives Electromagnetic Compatibility 2004 108 EC Directive 93 68 EC Year of CE marking 1999 Ulm 01 09 1999 Thomas Heinl Technical Dept Manager We expressly...

Страница 13: ...auf der R ck seite angegebene Serviceadresse Unfreie Paketeinsendungen wer den im Postverteilzentrum ausge filtert und erreichen uns nicht Nach erfolgter Reparatur senden wir das Ger t frei an Sie zur...

Страница 14: ...Colegios Moravia 200 metros al Sur del Colegio Saint Francis San Jos Phone 506 297 68 83 exim_euro racsa co cr Croatia SILK ADRIA d o o Josipa Lon ara 3 10090 Zagreb Phone 385 1 3794 580 silk adria z...

Страница 15: ...Portugal Lda Sintra Business Park Edif cio 1 Frac o 0 G 2710 089 Sintra Phone 351 21 922 85 30 info gardena pt Romania Madex International Srl Soseaua Odaii 117 123 RO 013603 Bucure ti S1 Phone 40 21...

Отзывы: