background image

3

4

2

1

3

8

4

7

1.  Screw extraction filter 

1

 onto the filter connection 

2

.

2.  Push the extraction tube provided 

3

 onto the filter 

connection 

2

 and screw air-tight with the hose clip 

4

.

3.  Push universal adapter 

5

 with seal 

6

 through the threaded 

nut 

7

 and screw onto the extraction-side connection 

8

.

4.  Push hose clip 

4

 onto the extraction hose 

3

, push extraction 

hose 

3

 onto the universal adapter 

5

 and screw air-tight with 

the hose clip 

4

.

6 5

7

4

3

Connect the delivery hose:

4

7

0

9

The delivery connection of the pump is fitted with a 33.3mm (G1) 
thread to which you can connect 13mm (1/2"), 16mm (5/8") or 
19mm (3/4") hoses using the GARDENA hose connection system 
fittings.

1.  Push universal adapter

 5

 with seal 

6

 d through the threaded 

nut 

7

 and screw onto the pressure-side connection 

9

.

2.  Push hose clip 

4

 onto the pressure hose 

0

, push pressure 

hose 

0

 onto the universal adapter 

5

 s and screw air-tight with 

the hose clip 

4

.

For the best delivery capacity, connect 19mm (3/4") hoses 
 together with GARDENA “Profi” System Fittings (e.g. 

Art. 1752

or 25mm (1") hoses together with GARDENA Brass Connection 
Fittings (e.g. 

Art. 7142

).

Connecting several pressure 
hoses in parallel:

When connecting several hoses or accessories in parallel 
we recommend using the GARDENA Twin-Tap Connector or 
Four Channel Water Distributor 

Art. 8193 / 8194 / 940

.

v

  Screw the Twin-Tap Connector or Four Channel Water 

 Distributor directly onto the thread of the delivery 
connection 

9

.

4. Operation

Prime pump:

1

1.  Install the pump at a safe distance from the pumping 

 medium. Install the pump level with the ground when the 
motor is switched off.

2.  Check petrol level (2-stroke mixture 40 : 1) 

(see 6. Maintenance).

3.  Check the air filter (see 6. Maintenance).

4.  Immerse extraction filter 

1

 in the pumping medium.

Fill the pump with the liquid 
to be pumped:

Fill the pump with approx. 1.5 litres of the liquid to be pumped 
before operating the pump.

!

B

1.  Unscrew the cover 

q

 from the filler neck 

w

 for the liquid to be 

pumped.

2.  Completely fill the pump chamber with pumping fluid via the 

filler nozzle 

w

 (approx. 1.5 l).

3.  Replace the cover 

q

 on the filler neck 

w

 and screw tight by 

hand.

Start the motor:

v

  Before starting, always prime the pump and fill the pump 

with pumping fluid (see above).

D

STOP

E

C

F

H

G

Start cold motor:

 1.  

Set ignition switch 

e

 to “

I

” 

(on).

 2.  

Press starter ball pump 

r

 

10 x. 

 3.  

Set choke lever 

t

 to 

Start

 

position.

 4.  

Set throttle control 

z

 to 

Max

 position.

 5.  

For optimum suction 
 capacity, fix pressure hose 
for start 1 – 2 m high.

 6.  

Press pump down firmly on 
bow 

u

 and pull the starter 

handle 

i

 until slight resist-

ance is felt. Then pull firmly 
on the starter handle 

i

.

 7.  

Guide starter handle 

i

 back 

slowly by hand so that the 
starter is not damaged (do 
not allow to spring back).

 8.  

Repeat points 6 and 7 
until the motor has 

briefly

 

started. 

 9.  

Set choke lever 

t

 to 

1/2

 

position. 

10.  Repeat points 6 and 7 until 

the motor has started.

11.  Set throttle control 

z

 to 

1/2

.

12.  After a warming-up period of 

approx. 30 secs., set choke 
lever 

t

 to 

Run

 position.

13.  Set throttle control 

z

 to 

required pumping rate 
 between 

Min

 and 

Max

.

Start warm motor:

1.  Set ignition switch 

e

 to “

I

” 

(on).

2.  Set choke lever 

t

 to 

Run

 position.

3.  Set throttle control 

z

 to 

Min

 position.

4.  For optimum suction 

 capacity, fix pressure hose 
for start 1 – 2 m high.

5.  Press pump down firmly on 

bow 

u

 and pull the starter 

handle 

i

 until slight resist-

ance is felt. Then pull firmly 
on the starter handle 

i

.

6.  Guide starter handle 

i

 back 

slowly by hand so that the 
starter is not damaged (do 
not allow to spring back).

7.  Repeat points 5 and 6 until 

the motor has started.

8.  Set throttle control 

z

 to 

required pumping rate 
 between 

Min

 and 

Max

.

v

  If the motor does not start, see 7. Troubleshooting.

Running the motor in:

The motor only reaches its maximum output 5 – 8 hours after 
 initial start-up. During this time, the motor must not be operated 
at full speed. This could damage the motor.

14

GB

15

GB

Содержание 9000 aquasensor

Страница 1: ...Használati utasítás Benzinmotoros szivattyú 9000 3 Art 1436 CZ Návod k obsluze Benzínové motorové čerpadlo SK Návod na obsluhu Čerpadlo s benzínovým motorom GR A RUS Инструкция по эксплуатации Бензомоторный насос SLO Navodilo za uporabo Bencinska vodna črpalka UA Інструкція з експлуатації Бензинова мотопомпа HR Uputa za upotrebu Motorna benzinska pumpa TR Kullanma Kılavuzu Benzin motorlu pompa RO ...

Страница 2: ...h naked flames or sparks when pouring petrol into the fuel tank of your pump or in places where petrol is stored v During operation and until the motor has cooled down completely do not place flammable materials e g petrol and objects near the pump v Do not overfill the fuel tank when filling your pump with petrol v Close the fuel tank securely after filling your pump with petrol v Wipe off any sp...

Страница 3: ...iquid to be pumped before operating the pump B 1 Unscrew the cover q from the filler neck w for the liquid to be pumped 2 Completely fill the pump chamber with pumping fluid via the filler nozzle w approx 1 5 l 3 Replace the cover q on the filler neck w and screw tight by hand Start the motor v Before starting always prime the pump and fill the pump with pumping fluid see above D STOP E C F H G St...

Страница 4: ...tion Each year or every 300 hours of operation Air filter check X clean X1 Clean adjust spark plug X Replace petrol filter X Clean combustion chamber and fuel tank X2 Check fuel hose turbine housing cover and backflow preventer replace if necessary X2 1 Carry out maintenance more frequently if using the pump in a dusty environment 2 This maintenance work must only be carried out at a GARDENA Servi...

Страница 5: ...ine clogs it must be cleaned 1 Unscrew the 6 Allen screws W of the housing cover X with an Allen key size 10 2 Remove housing cover X 3 Clean the turbine 4 Mount the housing cover X in the reverse order Disassembly of the hydraulic unit other than removing the housing cover must only be carried out by GARDENA Service Problem Possible Cause Remedy The motor does not start The ignition switch e is n...

Страница 6: ...eristic value LpA 1 90 dB A Noise level LWA 2 measured 102 dB A guaranteed 105 dB A Measuring method according to 1 DIN 45635 1 2 directive 2000 14 EC 10 Service Warranty Warranty GARDENA guarantees this product for 2 years from date of purchase This guarantee covers all serious defects of the unit that can be proved to be material or manufacturing faults Under warranty we will either replace the ...

Страница 7: ...piración de 25 mm 1 As características da bomba foram medidas a uma altura de sucção de 0 5 m e utilizando uma mangueira de aspiração de 25 mm 1 Dane w zakresie wydajności w charakterystyce pompy mierzone są przy wysokości zasysania 0 5 m i zastosowaniu przewodu ssącego 25 mm 1 A szivattyú jelleggörbe teljesítményadatait 0 5 m szívómagasságnál és 25 mm es 1 szívótömlő használatánál mérték Výkonová...

Страница 8: ...izadas A responsabilidade tornar se à nula também depois de reparações realizadas por oficinas não autorizadas pela GARDENA Esta restrição valerá também para peças adicionais e acessórios X Odpowiedzialność za produkt Informujemy że zgodnie z ustawą o odpowiedzialności cywilnej za szkody powstałe w związku z wadliwością towaru nie ponosimy odpowiedzialności za szkody powstałe w wyniku użytkowania ...

Страница 9: ...g aan de apparaten verliest deze verklaring haar geldigheid S EU Tillverkarintyg Undertecknad firma Husqvarna AB 561 82 Huskvarna Sweden intygar härmed att nedan nämnda produkter överensstämmer med EU s direktiv EU s säkerhetsstandard och produktspecifikation Detta intyg upphör att gälla om produkten ändras utan vårt tillstånd Q EU Overensstemmelse certificat Undertegnede Husqvarna AB 561 82 Huskv...

Страница 10: ...lsi 1 110 Reykjavik ooj ojk is Ireland McLoughlins RS Unit 5 Norther Cross Business Park North Road Finglas Dublin 11 Italy GARDENA Italia S p A Via Santa Vecchia 15 23868 Valmadrera LC Phone 39 0341 203 111 info gardenaitalia it Japan KAKUICHI co Ltd Sumitomo Realty Development Kojimachi BLDG 8F 5 1 Nibanncyo chiyoda ku Tokyo 102 0084 Phone 81 0 3 3264 4721 m_ishihara kaku ichi co jp Latvia 82 9 ...

Отзывы: