TR-RT LED lighting controllers - User Manual
STc
Where:
c
= the input channel (1 to 2, 4, or 8 depending on model).
This reports the settings for a single channel.
Simulate an Input Trigger
TRc
Where:
c
= the input channel (1 to 2 or 4, depending on model).
This simulates a trigger pulse. If the channel is in pulse mode it
pulses the output once.
Enable Ethernet Messages
GTm
Where:
m
= 0 to disable Ethernet messages, or
m
= 1 to enable Ethernet messages.
When Ethernet messages are enabled, any error reports are sent to
the most recent UDP or TCP address from which a command has
been received. Messages are of the form:
Evtc,e
Where:
c
= the channel number (1 to 2, or 4), or 0 for no channel
e
= event value (see
).
Clear any Errors
GR
If Ethernet messages are not enabled, the last event or error number
can be read by this command. Any error displayed on the unit is
cleared, so if there was a lighting error, the TR-RT resumes auto-
sensing on that channel.
The reply is in the same form as the
GT
command above. If there are
no outstanding events or errors, then only the prompt
>
is returned.
Set/Clear the Webpage Password
EY
EY asc1, asc2, asc3, asc4, asc5, asc6
This command sets the password required to access the
webpages. If
EY
is entered on its own then the password is cleared.
There are six optional parameters, which are decimal ASCII values
for a password from one to six letters. A value of 65 is ‘A’, 66 is ‘B’,
and so on, to 90 is ‘Z’.
—
35
—