TR-RC1xx - User Manual
Simulate an input trigger
TR1
This command simulates an input trigger. If the TR-RC is in pulse
mode, it pulses the output once.
Enable Ethernet messages
This command enables or disables Ethernet messages. Type in:
GTm
Where:
m
= 0 to disable Ethernet messages, and
m
= 1 to enable Ethernet messages.
When Ethernet messages are enabled, any error reports are sent to
the most recent UDP or TCP/IP address from which a command
has been received. These messages take the form:
Evtc,e
Where:
c
— 1 for events concerning the light output, otherwise 0
e
— the event value (see
)
Clear any errors
Use this command to read the last event or error code when
Ethernet messaging has been disabled:
GR
Any error displayed on the TR-RC is cleared. If this was a lighting
error, the unit resumes auto-sensing. If there are no outstanding
events or errors, the ‘
>
’ prompt is returned.
Set/Clear the webpage password
This command sets the webpage password. Up to six characters
can be chosen. Type in:
EYasc1,asc2,asc3,asc4,asc5,asc6
Where:
asc1
to
asc6
are decimal ASCII values for the letters of your
password
For example, a value of 65 is ‘A’, 66 is ‘B’ and so on up to 90 for ‘Z’.
Note:
When you use this password to access the TR-RC through the
webpage, you must use the actual characters and not the ASCII
values. Use upper case characters and do not enter commas or
spaces.
—
35
—