O
u
tp
u
t
M
o
d
e
In
p
u
t
G
at
e
In
p
u
t
P
u
ls
e
D
el
ay
P
u
ls
e
W
id
th
R
et
ri
g
g
er
T
im
e
F
la
g
s
1
2
1
0
200ms
100us
0
2
2
1
0
10 seconds
1 second
0
E, F,
R, P
(120)
6.4
Cold Boot
A cold boot function is available to reset the CC320 to a known state. The unit can be cold
booted as follows:
•
Press and hold the SEL and DOWN buttons when powering up the unit
•
Sending an Ethernet command
•
Pressing a button on an internal webpage
When the unit is cold booted it is set to the following state:
•
IP0 (free running trigger) is set up as a 1Hz internal trigger
•
The unit is set up for no encoder input
•
OP1 triggers from IP1, delay for 100ms then pulse for 100ms
•
OP2 triggers from IP2, delay for 100ms then pulse for 100ms
•
OP3 triggers from IP3, delay for 100ms then pulse for 100ms
•
OP4 triggers from IP4, delay for 100ms then pulse for 100ms
•
OP5 triggers from IP5, delay for 100ms then pulse for 100ms
•
OP6 triggers from IP0, delay for 100ms then pulse for 100ms
•
OP7 triggers from IP0, delay for 200ms then pulse for 100ms
•
OP8 triggers from IP0, delay for 300ms then pulse for 100ms