EN
3 - INSTRUCTIONS FOR USE
MA
0 1 1
206
PRE
ERR
26
PROGRAMS (STAGE)
The oven must be in the card-turned-on position with
the temperature display flashing (initial stage).
Pressing the
P
key you access programming and the
relevant display flashes waiting for the values to be set.
Using the
+
or
-
keys you select the program.
To go back to manual mode you press the
+
or
-
key to
set
MA
and confirm it pressing the
P
key to confirm or
wait for 15 seconds.
PROGRAMS
The user can set 20 programs (from 1 to 20) and the pro-
grams are displayed in numerical order. You can set 6
stages for every single program.
Setting a new program
-
Choose program number:
press the
P
key, the program display flashes, with the
+
or
-
keys select the program number to store or change,
wait for confirmation for 15 seconds or confirm by pres-
sing the
P
key.
-
Insert program number:
After having selected the program keep the
P
key pres-
sed to access the program, then you are back to the va-
lue setting stage of the manual mode.
If the program is blank the displays behave as in the ma-
nual procedure, ready to receive the values; if instead
there is an already stored program the relevant displays
show the inserted values.
The value setting procedure is performed as usual; if you
want to insert another stage keep the
F
key pressed,
with the plus keys you select the following stage and
you turn back to the usual value setting procedure and
do the same
for all the following stages.
It is not necessary to insert all the six stages in order to sto-
re a program. To store a program keep the
P
key pressed.
-
Temporary variation:
even in the program cycle, by pressing the temperature,
time, humidity keys, it is possible to modify the inserted
value without changing the initially stored program.
SPECIAL COMMANDS
Manual humidification key
Operation with only one active cycle.
Keeping the drying/humidification key pressed for 3 se-
conds the humidification display shows the time in secon-
ds, for a maximum of 10 seconds.
The relevant relay is activated and, once the key is released,
the display shows the previously set humidity percentage.
It is not active when the chamber temperature is below
100 °C.
The key does not have any effect if the oven is stopped.
Alarms
the following alarm cases
are provided:
“
Pr1
” chamber probe
open or in short-circuit;
“
Pr2
” core probe open or
in short-circuit or missing;
“
Pr5
” the display card and
the power card do not in-
teract with one another.
“
Pr
” is shown on the tem-
perature display;
“
ERR
” is shown on the
time display.