Locking door after power failure: An advanced technology with 

patent.  If  power  failure  occurs  while  the  door  is  opening,  the 

door can be released by pulling the clutch down, moving the 

door  to  the  closed  position  manually,  the  door  can  then  be 

locked. By pressing the button on the remote when the power 

comes  on  again,  the  door  can  be  opened  while  the  clutch 

moves  to  the  closed  position.  After  this,  normal  operation  is 

resumed. 

 

 

Rolling code: integrated circuit with specialized rolling code. No 

same  code,  high  security,  which  can  be  equipped  with  20 

transmitters; 

 

 

Travel  memory:   limited  journey  will  be  kept  in  its  mind 

automatically by the microcomputer. You don’t need to adjust 

it again even after power failure occurs.     

 

 

Soft  start  &  stop  which  will  lessen  the  impact  to  the  door, 

prolong the service life of the motor and decrease motor noise. 

 

Содержание S3

Страница 1: ...GARAGE DOOR OPENER OWNER S MANUAL S3...

Страница 2: ...in the door can be opened while the clutch moves to the closed position After this normal operation is resumed Rolling code integrated circuit with specialized rolling code No same code high security...

Страница 3: ...three modes for option forbidden available or only available when closing Auto closing mode If you forget to close the door it will closed automatically after a time The time can be set for 1 to 9 min...

Страница 4: ...Installation of door opening limit 5 4 Adjustment instructions 6 4 1 Ready status 6 4 2 Operation instructions 6 4 3 Adjusting methods 6 4 4 Advanced setting 8 4 5 Fault information 8 5 Locking door b...

Страница 5: ...ldren play with transmitters or remote controls and place these items out of reach of children 5 Test the automatic reversal monthly The garage door MUST reverse on contact with a 40mm high object or...

Страница 6: ...onal or one piece tilt doors 8 To avoid damage to the garage door and operator disable locks before installing and operating the operator 9 Prior to installation check for and avoid any damaging of co...

Страница 7: ...ional rails as shown in Figure 2 put them in line on a clean and flat floor as shown in Figure 3 Connect the sectional rails as shown in Figure 4 finish it as shown in Figure 5 3 3 2 Fixing belt As sh...

Страница 8: ...te as shown in Figure 9 L is about 100mm keep the bolts loose in order to adjust the L length 3 5 Hoisting the opener 3 5 1 Install the front bracket As shown in Figure 10 determine the installation l...

Страница 9: ...vely connect the straight drawbar and clutch bent drawbar and door bracket then pull down the rope on clutch to release it move the clutch base to the position as shown on Fig 14 then use bolts to loc...

Страница 10: ...on 4 3 2 Auto detect Press the lamp begins to flash the Opener goes toward the opening direction automatically stops at the mechanical open limit position It will then automatically move toward the cl...

Страница 11: ...hile closing 2 valid while both closing and opening 4 3 7 Auto close Press the P button until LED shows as Fig23 Pressing and will adjust the auto closing time by adjusting the value from 0 to 9 After...

Страница 12: ...ng and get out of the setting situation automatically 4 5 Fault information This opener can auto detect any errors during running and will display the error information When an error occurs LED screen...

Страница 13: ...work 6 2 Wall button installation Please refer to step 4 3 8 for programming of remote wall switch Wall switch must be installed where you can clearly see the operation of the door and must be 1 3m ab...

Страница 14: ...hnical data a Max output power 200 W b Max lifting force 600 N c Opening and closing speed 160 mm s d Light 12 V high light LED e Motor DC 24 V f Remote control distance 30 m g Remote frequency 433 92...

Страница 15: ...ystem Inspect and adjust the door balance system increase door closing load The door won t run in the closing door direction LED display 4 The photo beam is shielded System started to use photo beam s...

Страница 16: ...12 Distributed in New Zealand by Newfield Group PO Box 11303 Christchurch New Zealand www garageace co nz 0800 600 789...

Отзывы: