44 Installation and operating instructions
11.
Extended operator functions
Legend:
LED on
LED pulses
Factory default setting
LED off
LED flashes quickly
LED flashes quickly
–
Not possible
Level 8 – System settings
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Menu 1:
Photocell
A1
B1
C1
D1
–
–
–
–
–
–
–
–
–
–
–
–
Menu 3:
Automatic cut-out
A3
B3
C3
D3
–
–
–
–
–
–
–
–
–
–
–
–
Menu 4:
Operating modes
A4
B4
C4
D4
–
–
–
–
–
–
–
–
–
–
–
–
Menu 5:
Function of the direction command transmitters
A5
B5
–
–
–
–
–
–
–
–
–
–
–
–
–
–
Menu 6:
Function of the impulse command transmitters
A6
B6
–
–
–
–
–
–
–
–
–
–
–
–
–
–
Attention!
If a photocell is connected, it is automatically recognised by the controls after MAINS ON.
The photocell can be reprogrammed later.
Menu 1: Photocell
Setting
Photocell 1
(Connection XP020)
Door movement, CLOSE
Photocell 2
(Connection XB01 - Terminal 70/71)
Door movement, CLOSE
A1
Operation without photocell
B1
Door reverses completely
2
not active
C1
not active
Door reverses completely
2
D1
Door reverses completely
2
Door reverses completely
2