![Gap Diagnostic IIDTool Pro G3 Скачать руководство пользователя страница 146](http://html2.mh-extra.com/html/gap-diagnostic/iidtool-pro-g3/iidtool-pro-g3_user-manual_5057204146.webp)
146
GAP Diagnostic 2023-09-12 All Rights Reserved
User Manual G3 units: Version 37, Firmware V4.0
Figure 78.
LV : Start time
The record will contain all data for all values received X seconds before
the start trigger.
Figure 79.
LV : Stop time
The record will contain all data for all values received X seconds after
the stop trigger.
Figure 80.
LV : Target
Figure 81.
LV : Trigger when increasing and exceeding the threshold.
This symbol indicates that the trigger will be in effect when the observed live value increases
and crosses the defined target. For example, if the target value is set at 0, a change from
-1 to 0 will fulfill the condition. Available for analog live values.
Figure 82.
LV : Trigger when decreasing and crossing the threshold.
This symbol indicates that the trigger will be in effect when the observed live value de
-
creases and crosses the defined target. For example, if the target value is set at 0, a
change from 1 to 0 will fulfill the condition. Available for analog live values.
Figure 83.
LV : Trigger when the value and target are equal.
This symbol indicates that the trigger will be in effect when the observed live value changes
and becomes the defined threshold point. For example, if the threshold value is set at 0, a
change from -1 to 0 (or 1 to 0) will fulfill the condition. Available for state live values.
Figure 84.
LV : Trigger when the value and target are not equal.
This symbol indicates that the trigger will be in effect when the observed live value changes
from being equal to the target value to not equal. For example, if the threshold value is set
at 1, a change from 1 to 0 will fulfill the condition. Available for state live values.
Trigger enabling
Click on the T symbol to enable or disable the trig
-
gers. Once a recording as begun automatically, it
can be stopped like a regular recording by clicking
on the stop button.
Figure 85.
LV : Trigger enabling