BLE pulse period activation
Period between radio pulses in activation mode. Input in
100 ms (e.g. 600 = 1 min.). As each pulse requires
energy, the period should be selected so that wireless
signals are still quickly detectable in activation mode.
Integer
5
BLE PreLock Timeout
Period to lock the GL7p after a wireless command. Input
in seconds.
Integer
10
KeyPad
General
KeyPad enabled
When set to "True", entry via PIN code is possible for the
GL7p.1xxx and GL7p.3xxx locks
Boolean
False
Pin code timeout
Max. input time between 2 digits of the PIN code. If no
additional key is pressed during this time and the entry is
not confirmed with (
✓
) or button, the entry is cancelled.
Input in 100 ms (e.g., default value 40 = 4 seconds).
Integer
40
Minimum PIN length
Minimum required PIN code length
Integer
4
Maximum PIN length
Minimum required PIN code length
Integer
8
Activate pin code UseTimeLimit
When set to "True", the usage duration is used for PIN
code entry, analogous to the operation with data carriers.
See "6.3.1. Free Locker Mode (with or without Duration of
Use Function)"
Boolean
False
Application
General
Legacy BasicSetCoding
When set to "True", data carriers in the Basic Set are
coded for a predecessor system (previous coding)
Boolean
False
Master cards
MasterCard1 - 10
Fields to enter number for MASTER data carrier 1-10
Integer
License
License CertificateCheck
When "installed" is displayed here, the certificate check
can be switched on/off.
Info
CertificateCheck enabled
Switch on/off the certificate check for data carriers
Boolean
False
Read only parameter
Production
Production-specific information about the GL7p
ArticleNum
Part number of the lock
Integer
SerialNum
Serial number of the lock
Integer
ManufacturerNum
Manufacturer number of the lock
Integer
ProductionYear
Production year of the lock
Integer
ProductionWeek
Production week of the lock
Integer
HardwareUidNum
Unique ID number of the lock
Integer
ControllerType
Type number of the lock
HardwareVers
Hardware version of the lock
Integer
BootloaderVers
Bootloader version of the lock
Integer
FirmwareVers
Firmware version of the lock
Integer
LockEngineVers
Version of the lock logic
Integer
Internal
Internal data for service purposes
Antenna matching
Antenna calibration
Integer
CNT Activation
Number of button actuations since resetting the counter
Integer
CNT Locking
Number of valid locks (with data carrier or PIN) since
resetting the counter
Integer
CNT Activation ABS
Total number of button actuations
Integer
CNT Locking ABS
Total number of locks (with data carrier or PIN)
Integer
Temp. int.
Temperature in the GL7p in °C
Integer
BV
Information for service technicians
TL
Information for service technicians
MC
Information for service technicians