POOL/SPA MODES

  

The  control  is  equipped  with  two  independent  thermostats,  one  for 

pool temperature and one for spa temperature.  This is to allow user 

to preset a temperature of their choice and switch between the two 
settings with the 

“MODE” button located on the control. When water is 

flowing  through  the  unit  and  the  water  temperature  meets  the 

specified set point condition, the control will turn off the heater.  
 

If you do not have a spa, you can use the spa thermostat as a second 

temperature setting if you do not want to maintain full temperature all 

the time.  For instance, if you swim on the weekends only, you can set 
the temperature back during the week to save costs but maintain a 

warmer temperature for a shorter recovery time for the weekend.  

 

The display on the control will show the thermostat being used and the 

operating mode on the top line and the current water temperature on 
the bottom line.  The Standard mode displays are:  

“POOL – HEAT”, “SPA – HEAT”, ”POWER OFF”. 

 

 “POOL-COOL”, “POOL- HEAT/COOL”, “POOL SOLAR HEAT” will also be 

available  if  enabled  in  the  service  menu.  Addition  programming  and 

wiring may be required for these features to be activated. 

 

 

CHANGING SET POINT TEMPERATURE

  

To change the set point temperature, press either the 

“Up” or “Down” 

arrow buttons on the control.  The display will then show 

“POOL or SPA 

TEMPERATURE SET POINT” on the top line and the current set point 

temperature  in  numbers  on  the  bottom  line.  After  adjusting  to  the 

desired temperature setting, the display will revert to 

“POOL or SPA – 

HEAT”  on  the  top  line  and  the  pool  temperature  in  numbers  with 

“DEGREES” on the bottom line. After 5 seconds of inactivity and the 

new set point will be stored in memory. The default factory setting for 

Pool temperature is 85˚ Fahrenheit (F).  

 

  

 

ATTENTION: 

 

 

There is a 120 Second time delay upon initiation of a heating cycle.  

This is to ensure that the critical components do not fail due to 

short cycling of the heater. A count down will be provided on the 

display. 

Содержание 5005001B

Страница 1: ...Swimming Pool Heat Pump Install Operation Manual 5005001B Version 5 5 For fastest service please be sure to complete the information below and call 239 567 0009 Serial ___________________ Install Date...

Страница 2: ...Valve Automation 9 o Plumbing Sequence 9 Heat Pump Features 10 Heat Pump Operation 11 o Control On Off 11 o Pool Spa Modes 12 o Changing Set Point Temperature 12 o Heater Running Time 13 o Keypad Loc...

Страница 3: ...Schedule service on line at www Gulfstreamheatpump com Service can also be obtained by calling us at 239 567 0009 or 954 318 6900 When asking for help or service please provide a detailed description...

Страница 4: ...in use The pool cover should be used if the night temperature is 15 F 8 C less than the desired pool temperature This will keep evaporation the greatest source of heat loss to a minimum greatly reduc...

Страница 5: ...2 to 3 days Total Alkalinity 80 to 120 PPM 1 time every 2 to 3 weeks Total Dissolved Solids Below 2400 PPM 1 time per month Calcium Hardness 200 to 300 PPM 1 time per month The location of the chemica...

Страница 6: ...he heater should have at least 12 inches of clearance to allow enough air to flow through the evaporator coil for optimal heating Restricting one side of the evaporation coil is permitted however it w...

Страница 7: ...ight corner of the board See Diagram FS1 Whitwires from the Water Pessure Diagram FS1 Sub Menu Access To access the programming sub menu remote t stat solar heat cool calibration load defaults etc pre...

Страница 8: ...es the desired set point The new sensor must be attached to the board on the spades where the current WTS is attached Enabling the Solar Control Press and hold the UP and the DOWN arrows till the serv...

Страница 9: ...to Spa This can also be activated by a network communicating switch via an App on your mobile device Additional wiring required Call service more additional wiring and details of this feature Diagram...

Страница 10: ...ic low temperature defrosts remote control capabilities even heat motorized valve operation and solar control ULTRA QUIET The unit is equipped with a low RPM fan motor in combination with a deep drawn...

Страница 11: ...eature is after paired with SOLAR CONTROL Additional wiring required The board can be set to run and monitor your pool solar system There is no need to have a second and separate control system page 8...

Страница 12: ...perature on the bottom line The Standard mode displays are POOL HEAT SPA HEAT POWER OFF POOL COOL POOL HEAT COOL POOL SOLAR HEAT will also be available if enabled in the service menu Addition programm...

Страница 13: ...in whatever mode it was in when the lockout occurred Any button push while in LOCKED will cause the display to show LOCKED for 5 seconds To unlock the Keypad press and hold the MODE button for 6 secon...

Страница 14: ...8 2 F Illustration 2 By pressing the MODE button once your pool temp set point has been set you will see POOL SOLAR HEAT SETPOINT on display as in illustration 3 P O O L S O L A R H E A T S E T P O I...

Страница 15: ...en reads POOL TEMPERATURE SETPOINT 3 Use the UP or DOWN arrow until desired temperature is on display 4 While still in the POOL TEMPERATURE SETPOINT screen press the MODE button to set the DEADBAND Th...

Страница 16: ...assure proper condensation drainage Your heat pump s cabinet is made from a maintenance free rust free plastic that is UV resistant It will last for years and any dirt or dust may be wiped away with a...

Страница 17: ...it is normal condensation If water still coming out of the bottom of the unit then you may have a water leak inside of the unit Also a pool test strip can detect chlorine if a water leak is suspected...

Страница 18: ...s activated Call For service Unit Displays Max Water Temperature Check to make sure you do not have a secondary source of heat feeding hot water into the unit If no secondary source of heat call for s...

Страница 19: ...19 Pool Heater Wiring Diagram...

Страница 20: ...20...

Страница 21: ...21 Notes...

Страница 22: ...ne at www Gulfstreamheatpump com Service can also be obtained by calling us at 239 567 0009 or 954 318 6900 When calling for help or service please provide a detailed description of the problem your h...

Отзывы: