12
POOL/SPA MODES
The control is equipped with two independent thermostats, one for
pool temperature and one for spa temperature. This is to allow user
to preset a temperature of their choice and switch between the two
settings with the
“MODE” button located on the control. When water is
flowing through the unit and the water temperature meets the
specified set point condition, the control will turn off the heater.
If you do not have a spa, you can use the spa thermostat as a second
temperature setting if you do not want to maintain full temperature all
the time. For instance, if you swim on the weekends only, you can set
the temperature back during the week to save costs but maintain a
warmer temperature for a shorter recovery time for the weekend.
The display on the control will show the thermostat being used and the
operating mode on the top line and the current water temperature on
the bottom line. The Standard mode displays are:
“POOL – HEAT”, “SPA – HEAT”, ”POWER OFF”.
“POOL-COOL”, “POOL- HEAT/COOL”, “POOL SOLAR HEAT” will also be
available if enabled in the service menu. Addition programming and
wiring may be required for these features to be activated.
CHANGING SET POINT TEMPERATURE
To change the set point temperature, press either the
“Up” or “Down”
arrow buttons on the control. The display will then show
“POOL or SPA
TEMPERATURE SET POINT” on the top line and the current set point
temperature in numbers on the bottom line. After adjusting to the
desired temperature setting, the display will revert to
“POOL or SPA –
HEAT” on the top line and the pool temperature in numbers with
“DEGREES” on the bottom line. After 5 seconds of inactivity and the
new set point will be stored in memory. The default factory setting for
Pool temperature is 85˚ Fahrenheit (F).
ATTENTION:
There is a 120 Second time delay upon initiation of a heating cycle.
This is to ensure that the critical components do not fail due to
short cycling of the heater. A count down will be provided on the
display.