background image

 

  

WARNING:

  

 

Non-authorized service may void the warranty. 

REGISTER YOUR WARRANTY ONLINE AT: 

http://gulfstreamheatpump.com/register

 

SERVICE 

All  warranty  service  must  be  handled  by  an  Authorized  Service  Center.  

Warranty may be void if a non-authorized service representative does service 
on the unit.  Do not return the heater to your dealer, as they do not provide 

service.  Before  calling  for  assistance  or  service,  please  check  the 

Troubleshooting section of this manual or call your dealer.  This may save you 

the cost of a service call.  If you still need help, follow the instructions below.  

 

Schedule service on-line at: 

www.Gulfstreamheatpump.com

 

 

Service can also be obtained by calling us at:  

(239) 567-0009 or (954) 318-6900 

 

When asking for help or service please provide a detailed description of the 

problem, your heater’s complete serial number, the purchase date and dealer 

purchased  from.    This  information  will  help  us  respond  properly  to  your 
request.  

 

   Keep a copy of the sales receipt with the date of purchase.

 

Proof of purchase will verify in-warranty service. 

 

 

Attention, Warning, and Caution boxes have been place throughout 

manual to help point out important information to look out for. 

  

 

Attention

- this will point out important information to be 

aware of 

 

Warning

- this will point out action that might void 

warranty

 

 

Caution

- this will point out any safety issue for owners 

Содержание 5005001B

Страница 1: ...Swimming Pool Heat Pump Install Operation Manual 5005001B Version 5 5 For fastest service please be sure to complete the information below and call 239 567 0009 Serial ___________________ Install Date...

Страница 2: ...Valve Automation 9 o Plumbing Sequence 9 Heat Pump Features 10 Heat Pump Operation 11 o Control On Off 11 o Pool Spa Modes 12 o Changing Set Point Temperature 12 o Heater Running Time 13 o Keypad Loc...

Страница 3: ...Schedule service on line at www Gulfstreamheatpump com Service can also be obtained by calling us at 239 567 0009 or 954 318 6900 When asking for help or service please provide a detailed description...

Страница 4: ...in use The pool cover should be used if the night temperature is 15 F 8 C less than the desired pool temperature This will keep evaporation the greatest source of heat loss to a minimum greatly reduc...

Страница 5: ...2 to 3 days Total Alkalinity 80 to 120 PPM 1 time every 2 to 3 weeks Total Dissolved Solids Below 2400 PPM 1 time per month Calcium Hardness 200 to 300 PPM 1 time per month The location of the chemica...

Страница 6: ...he heater should have at least 12 inches of clearance to allow enough air to flow through the evaporator coil for optimal heating Restricting one side of the evaporation coil is permitted however it w...

Страница 7: ...ight corner of the board See Diagram FS1 Whitwires from the Water Pessure Diagram FS1 Sub Menu Access To access the programming sub menu remote t stat solar heat cool calibration load defaults etc pre...

Страница 8: ...es the desired set point The new sensor must be attached to the board on the spades where the current WTS is attached Enabling the Solar Control Press and hold the UP and the DOWN arrows till the serv...

Страница 9: ...to Spa This can also be activated by a network communicating switch via an App on your mobile device Additional wiring required Call service more additional wiring and details of this feature Diagram...

Страница 10: ...ic low temperature defrosts remote control capabilities even heat motorized valve operation and solar control ULTRA QUIET The unit is equipped with a low RPM fan motor in combination with a deep drawn...

Страница 11: ...eature is after paired with SOLAR CONTROL Additional wiring required The board can be set to run and monitor your pool solar system There is no need to have a second and separate control system page 8...

Страница 12: ...perature on the bottom line The Standard mode displays are POOL HEAT SPA HEAT POWER OFF POOL COOL POOL HEAT COOL POOL SOLAR HEAT will also be available if enabled in the service menu Addition programm...

Страница 13: ...in whatever mode it was in when the lockout occurred Any button push while in LOCKED will cause the display to show LOCKED for 5 seconds To unlock the Keypad press and hold the MODE button for 6 secon...

Страница 14: ...8 2 F Illustration 2 By pressing the MODE button once your pool temp set point has been set you will see POOL SOLAR HEAT SETPOINT on display as in illustration 3 P O O L S O L A R H E A T S E T P O I...

Страница 15: ...en reads POOL TEMPERATURE SETPOINT 3 Use the UP or DOWN arrow until desired temperature is on display 4 While still in the POOL TEMPERATURE SETPOINT screen press the MODE button to set the DEADBAND Th...

Страница 16: ...assure proper condensation drainage Your heat pump s cabinet is made from a maintenance free rust free plastic that is UV resistant It will last for years and any dirt or dust may be wiped away with a...

Страница 17: ...it is normal condensation If water still coming out of the bottom of the unit then you may have a water leak inside of the unit Also a pool test strip can detect chlorine if a water leak is suspected...

Страница 18: ...s activated Call For service Unit Displays Max Water Temperature Check to make sure you do not have a secondary source of heat feeding hot water into the unit If no secondary source of heat call for s...

Страница 19: ...19 Pool Heater Wiring Diagram...

Страница 20: ...20...

Страница 21: ...21 Notes...

Страница 22: ...ne at www Gulfstreamheatpump com Service can also be obtained by calling us at 239 567 0009 or 954 318 6900 When calling for help or service please provide a detailed description of the problem your h...

Отзывы: