5A.
TROUBLESHOOTING
CORRECT
SWITCH
DISPLAYS
VALVE CYCLE STATUS
-- --
Valve in service, fill, brining,
backwash or fast rince position
--P
Valve rotating from one posi-
tion to another
C
.
While in this diagnostic screen, the following
information is available and may be benefi-
cial for various reasons. This information is
retained by the computer from the first time
electrical power is applied to the face plate.
- - Press to display the number of days this
face plate has had electrical power applied.
- - Press to display the number of regenera-
tions initiated by this face plate since the SC
code number was entered.
2
.
Press Select to advance to the following
alternating displays.
This setting controls the length of the back-
wash cycle (regular recharge backwash, and
the CLEAN feature backwash if set to ON). A
longer backwash is beneficial if supply water
is dirty, or contains iron. The time is adjust-
able up to 5 minutes. Use the UP or DOWN
button to set.
3
.
Press the SELECT button and hold 3 seconds
until
…
. . .
SC20
shows.
This code identifies the softener nominal capac-
ity size. If the wrong number shows, the softener
will operate on incorrect programming. Do the
following as needed.
RETURNTHE PRESENT TIME DISPLAY -
Press the
SELECT button.
CHANGE THE SC NUMBER - Press the UP or
DOWN button to display correct number; press
SELECT, and reset the timer.
NOTE:
If the face plate is left in a diagnostic display (or a flashing
display when setting times or hardness), time of day
automatically returns if a button is not pressed within 4
minutes.