34
disturbing the transmission it can absolutely happen that some commands are received and others are
not. This applies also for the display of the warning. Due to that you should take care for good range
and operating conditions so that the warning signal will be displayed reliably.
24. The menu
Certain menu function of the G-Flame are depending on the selected control method. In this chapter
we will first explain the standard menu with all standard menu items. The control variants 'Firing key'
and '12-24V' will be described. Later the menu items of the other control methods will be explained.
24.1. Standard menu items
24.1.1. The menu item 'Language'
Sprache/Language
English
Here you can select the language of the menu and all display texts of the
receiving mode or respectively the ready to fire mode.
24.1.2. The menu item 'Accumulator capacity'
You see e.g. this result in the display:
Accumulator
Capacity: 95%
In this example the remaining charging level is 95%. If the value decreases
below 30% the charging reserve is being touched. If the battery is being
discharged to 0% damages due to deep discharging are possible.
Note: The display of the accumulator capacity is related to an ambient temperature of 20°C. A fully
charged battery could also lead to a reading of e.g. 80% if the temperature is very low.
Note: The result of this menu item can also be displayed at the controller PFC Advanced by using the
function 'Remote data request', provided that the Advanced wireless module has been installed.
No result regarding the accumulator capacity can be acquired as long as the battery is being charged.
In this case you will see the following information in the display:
The accumulator
is being charged
The results may be higher directly after charging. We recommend to wait an
operation time of approx. 10 minutes to gain realistic results.
24.1.3. The menu item 'Accumulator power'
By activating 'Mode' you will proceed in the menu and see e.g. this text in the display:
Accumulator
Power: 99%
To get information regarding the battery power it is discharged with a very
high current for a short period of time. The device is analyzing the voltage
drop and recovery during this process and is then able to compare the
results in relation to an optimum value. The measured parameter is the
capability of delivering high current that can decrease during the chemical aging process of the
battery. A fully charged battery should have a result of at least 60%.
Note: The result of this menu item can also be displayed at the controller PFC Advanced by using the
function 'Remote data request', provided that the Advanced wireless module has been installed.
Содержание PYROTEC G-Flame
Страница 2: ...2...
Страница 12: ...12 6 Illustration and description of indicators and control elements 6 1 Main unit...