28.1.3. Flame monitoring on/off
Flame
monitoring: On
Here the flame monitoring system has been deactivated in the menu. The
device is measuring the ionization of the flame immediately after the
beginning of the ignition phase to determine if the flame is really burning
and if it has been completely ignited. If no flame is being detected for more
than one second the fuel valves will be closed.
Flame
monitoring: Off
In this example the flame monitoring has been disabled in the menu of the
device.
28.2. Display of special information and behavior of the device in
the receiving mode or respectively ready to fire mode if
'Wireless (PFC or PFS)' or 'Cable (RS485 of PFC)' has been
selected as control method
After the selected control method the status of the tilt switch and the flame monitoring system will be
displayed. Right after that the following screens will be visible:
28.2.1. Status information regarding firing mode and hazard zone
Firing Mode: Off
Hazard Zone: K
Firstly the status of the firing mode is being displayed (on or off). Please
note in this context that the device is assuming that the firing mode is
disarmed at the controller when being switched on. If the G-Flame is
powered after the firing mode has been armed 'off' will be displayed nevertheless. Furthermore, this
wrong usage leads to the detection of a radio interference because the G-Flame interprets the signal
of the controller as an interference. In addition the hazard zone the device has been assigned to plus if
this zone is active or not is being displayed (' ' = active, 'x' = inactive). The hazard zone is active by
default after powering up the device and must be deactivated by a command from the controller if
necessary.
If the status of one of these parameters is changing the device immediately jumps to this screen and in
addition the display backlight is switched on, if it has been enabled in the menu.
Note: Every time the firing mode is turned on or off the controller transmits this information to the
receiver. If the status of the firing mode is being changed the G-Flame can only display the current
status of the firing mode correctly if they are in the receiving mode and within radio coverage.
Note: If the firing mode is being switched off all possibly opened electromagnetic fuel valves are
closed (command 'Firing mode off'). In addition all stepping sequences that are currently in progress
are terminated, provided that the G-Flames are within radio range and that this information is being
received.
28.2.2. Display of the device ID number
Dev. ID No. for
bidir. Comm.: 15
Then the device ID number for bi-directional communication which has
been assigned to this device is being displayed.
Содержание PYROTEC G-Flame